Background: The use of simulators for endovascular aneurysm repair (EVAR) is not widespread. We examined whether simulation could improve procedural variables, including operative time and optimizing proximal seal. For the latter, we compared suprarenal vs infrarenal fixation endografts, right femoral vs left femoral main body access, and increasing angulation of the proximal aortic neck.
Methods: Computed tomography angiography was obtained from 18 patients who underwent EVAR at a single institution. Patient cases were uploaded to the ANGIO Mentor endovascular simulator (Simbionix, Cleveland, Ohio) allowing for three-dimensional reconstruction and adapted for simulation with suprarenal fixation (Endurant II; Medtronic Inc, Minneapolis, Minn) and infrarenal fixation (C3; W. L. Gore & Associates Inc, Newark, Del) deployment systems. Three EVAR novices and three experienced surgeons performed 18 cases from each side with each device in randomized order (n = 72 simulations/participant). The cases were stratified into three groups according to the degree of infrarenal angulation: 0° to 20°, 21° to 40°, and 41° to 66°. Statistical analysis used paired t-test and one-way analysis of variance.
Results: Mean fluoroscopy time for participants decreased by 48.6% (P < .0001), and total procedure time decreased by 33.8% (P < .0001) when initial cases were compared with final cases. When stent deployment accuracy was evaluated across all cases, seal zone coverage in highly angulated aortic necks was significantly decreased. The infrarenal device resulted in mean aortic neck zone coverage of 91.9%, 89.4%, and 75.4% (P < .0001 by one-way analysis of variance), whereas the suprarenal device yielded 92.9%, 88.7%, and 71.5% (P < .0001) for the 0° to 20°, 21° to 40°, and 41° to 66° cases, respectively. Suprarenal fixation did not increase seal zone coverage. The side of femoral access for the main body did not influence proximal seal zone coverage regardless of infrarenal angulation.
Conclusions: Simulation of EVAR leads to decreased fluoroscopy times for novice and experienced operators. Side of femoral access did not affect precision of proximal endograft landing. The angulated aortic neck leads to decreased proximal seal zone coverage regardless of infrarenal or suprarenal fixation devices.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jvs.2016.01.050 | DOI Listing |
J Endovasc Ther
January 2025
Aortic Center, Hôpital Marie-Lannelongue, Groupe Hospitalier Paris Saint Joseph, Université Paris-Saclay, INSERM UMR_S 999, Le Plessis Robinson, France.
Introduction: Management of patients with large aortic arch aneurysms who are considered high risk for frozen elephant trunk technique have been challenging, especially when they have a dilated ascending aorta (AA) that precludes total endovascular branched repair (arch BEVAR). A viable option in our armamentarium is wrapping of the AA (AW), and zone 0 Ishimaru TEVAR.
Methods: Retrospective analysis of our aortic database from 2013 to 2024 to select high-risk patients with aortic arch aneurysm that had an AW and TEVAR.
The combination of hip arthroscopy and periacetabular osteotomy (PAO) has been proven safe and effective for addressing symptoms in patients with developmental dysplasia of the hip (DDH). As not every patient with dysplasia will require a hip arthroscopy to obtain desired clinical improvement in the setting of periacetabular osteotomy, a challenge is identifying which patients require adjacent procedures (either via arthroscopic or open) to fully treat their hip pathology. Even though labral repair is the most reported arthroscopic procedure in cases of hip dysplasia, I would suggest that labral treatment is the least likely helpful component of hip arthroscopy in these cases.
View Article and Find Full Text PDFJ Vasc Surg
November 2024
Division of Vascular and Endovascular Surgery, Department of Surgery, Stanford University, Stanford, CA. Electronic address:
Proc Inst Mech Eng H
November 2024
School of Mechanical Engineering, Iran University of Science and Technology, Tehran, Iran.
Using ultrasound technology as one of the therapeutic methods, in which ultrasound waves of different frequencies and intensities are employed, has significantly contributed to enhancing and facilitating the treatment process of various diseases. A Hemostatic Ultrasonic Scalpel can entail considerable advantages by simultaneously performing two operations tissue cutting and coagulation of biological tissues. In the present study, employing experimental design through response surface methodology, the effect of ultrasonic power and the duration of vibration application on the tissue has been investigated.
View Article and Find Full Text PDFCureus
October 2024
Conservative Dentistry and Endodontics, All India Institute of Medical Sciences, Kalyani, Kalyani, IND.
Background The importance of achieving optimal sealing in endodontic procedures cannot be overstated, as it directly influences the success and durability of root canal treatments. The objective of this research was to measure and identify the sealing ability of endodontic sealers by evaluating their adhesion to root canal dentin and the extent to which they achieve a complete seal. Methods A total of 60 extracted lower premolar teeth were randomly divided into three groups of 20 samples each.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!