Background: The aim of this study was to evaluate the amount of nickel and titanium ions released from two wires with different shapes and a similar surface area.
Methods: Forty round nickel-titanium (NiTi) arch wires with the diameter of 0.020 in. and 40 rectangular NiTi arch wires with the diameter of 0.016 × 0.016 in. were immersed in artificial saliva during a 21-day period. The surface area of both wires was 0.44 in.(2). Wires were separately dipped into polypropylene tubes containing 50 ml of buffer solution and were incubated and maintained at 37 °C. Inductively coupled plasma atomic emission spectrometry (ICP-AES) was used to measure the amount of ions released after exposure lengths of 1 h, 24 h, 1 week, and 3 weeks. Repeated measures ANOVA and Tukey tests were used to evaluate the data.
Results: The results indicated that the amount of nickel and titanium concentrations was significantly higher in the rectangular wire group. The most significant release of all metals was measured after the first hour of immersion. In the rectangular wire group, 243 ± 4.2 ng/ml of nickel was released after 1 h, while 221.4 ± 1.7 ng/ml of nickel was released in the round wire group. Similarly, 243.3 ± 2.8 ng/ml of titanium was released in the rectangular wire group and a significantly lower amount of 211.9 ± 2.3 ng/ml of titanium was released in the round wire group.
Conclusions: Release of metal ions was influenced by the shape of the wire and increase of time.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4819061 | PMC |
http://dx.doi.org/10.1186/s40510-016-0123-3 | DOI Listing |
J Prosthodont
January 2025
The Office of Assistant Dean for Research, School of Dental Medicine, Medical Sciences Campus, University of Puerto Rico, San Juan, Puerto Rico.
Purpose: This study aimed to evaluate and compare the fracture resistance of long-span fixed provisional restorations fabricated using milling, three-dimensional (3D) printing, and conventional methods.
Materials And Methods: Sixty specimens were prepared, divided into four groups of 15 each, corresponding to four fabrication methods: computer-aided design and computer-aided manufacturing (CAD-CAM) milled provisional resins, 3D-printed provisional resins, 3D-printed permanent resins, and conventional bis-acryl restorations reinforced with wire. The specimens underwent a three-point bending test using a universal testing machine to measure fracture resistance, quantified as maximum force (in Newtons).
J Am Podiatr Med Assoc
January 2025
‡Canakkale Onsekiz Mart University Medical Faculty, Department of Orthopedics and Traumatology, Çanakkale, Turkey.
Background: The aim of study was to biomechanically compare the fixation of Jones fracture using headless cannulated screw, tension band, and two Kirschner wires.
Methods: A total of 60 fourth-generation, fifth metatarsal synthetic bone models were divided into three groups according to the fixation techniques. A vertical load, oriented from plantar to dorsal and lateral to medial, was applied to the metatarsal specimen that were potted with molding material.
J Clin Med
January 2025
Department of Cardiovascular Surgery, Houston Methodist Hospital, 6550 Fannin St, Houston, TX 77030, USA.
: The aim of this study was to compare the outcomes of stiff wire-based 2D3D, 3D3D image fusion (IF), and non-image fusion techniques for simple zone 2 and zone 3 TEVAR cases in terms of radiation exposure, contrast dose, and fusion and projection accuracy. : A single-center retrospective observational study was conducted based on data gathered from patients who underwent TEVAR between 2016 and 2023 at our tertiary aortic referral center. Those who underwent Z2 and Z3 TEVAR during the indicated period were included.
View Article and Find Full Text PDFMedicina (Kaunas)
January 2025
Department of Orthopedics and Traumatology, Karabük University, Karabük 78050, Turkey.
The study aimed to evaluate a newly designed semicircular implant for the fixation of Vancouver Type B1 periprosthetic femoral fractures (PFFs) in total hip arthroplasty (THA) patients. To determine its strength and clinical applicability, the new implant was compared biomechanically with conventional fixation methods, such as lateral locking plate fixation and a plate combined with cerclage wires. : Fifteen synthetic femur models were used in this biomechanical study.
View Article and Find Full Text PDFBeijing Da Xue Xue Bao Yi Xue Ban
February 2025
Second Clinical Division, Peking University School and Hospital of Stomatology & National Center for Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Research Center of Oral Biomaterials and Digital Medical Devices, Beijing 100101, China.
Objective: To compare the cyclic fatigue resistance of nickel-titanium files made by 3 new heat treatment in simulated S-shaped root canals at different temperatures.
Methods: Gold heat-treated nickel-titanium files TruNatomy (25 mm, tip size 26#/0.04) and ProTaper Gold (25 mm, tip size 25#/0.