Objective: Lifelong yearly surveillance is advised after endovascular aneurysm repair (EVAR) for abdominal aortic aneurysms. This follow-up requires a substantial amount of health care resources. The aim of this paper was to assess the occurrence of stent graft-related complications and secondary interventions during a minimum 10-year follow-up after elective EVAR.
Methods: Patients who were treated in a high-volume endovascular center in The Netherlands with the Talent infrarenal stent graft (Medtronic Vascular, Santa Rosa, Calif) between June 1999 and February 2005 were included. Patients with previous aortic surgery or emergency interventions were excluded. Our primary outcome was clinical success up to 10 years. Secondary end points were technical success and survival.
Results: A total of 149 patients were included; 91.9% were male. The mean age was 70.2 ± 7.8 years. A stent graft was implanted in 98% of patients; technical success was achieved in 89.9%. Clinical success after 30 days, 1 year, 5 years, and 10 years was 81.1%, 74.3%, 70.3%, and 65.5%, respectively. In 30 patients (20.7%), a secondary intervention was required; 80.0% of first secondary interventions occurred within the first 5 years. Six late conversions were necessary because of stent graft infection (2), migration (2), or persisting endoleak (2). The 5- and 10-year overall survival rates were 55.2% and 38.6%, respectively.
Conclusions: The risk of EVAR-related complication is highest in the first 5 years. Consequently, the main focus should be on that period; further follow-up must not be neglected, as complications occur up to 10 years after treatment.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jvs.2016.01.035 | DOI Listing |
J Vasc Surg Cases Innov Tech
April 2025
Division of Vascular and Endovascular Surgery, Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padua, Padua, Italy.
This report details the case of an 84-year-old male with an infrarenal abdominal aortic aneurysm and a dilated right common iliac artery eligible for endovascular treatment. A bifurcated stent graft (Medtronic Endurant IIs) was used to treat the aneurysm. To address the concerns of instability of the right iliac limb, four endoanchors (Heli-FX EndoAnchor, Medtronic) were placed at the distal landing zone to provide additional fixation.
View Article and Find Full Text PDFMedicine (Baltimore)
November 2024
Department of Vascular Surgery, the Second Affiliated Hospital, Jiangxi Medical College, Nanchang University.
Stanford type B aortic dissection involving the left subclavian artery (LSA) poses significant clinical challenges. The Castor single-branch stent graft and in situ fenestration are commonly used techniques, but the better endovascular treatment remains debated. This study evaluates the clinical effects of the Castor single-branched stent graft versus in situ fenestration in treating Stanford type B aortic dissection involving the LSA.
View Article and Find Full Text PDFClin Endosc
January 2025
Department of Gastroenterology, Ajou University School of Medicine, Suwon, Korea.
Surg Infect (Larchmt)
January 2025
Division of Thoracic and Cardiovascular Surgery, Department of Surgery, Chang Gung Memorial Hospital, Linkou Medical Center, Chang Gung University, Taoyuan City, Taiwan.
Stent graft infection (SGI) caused by complex is rare. The usage of ascending-to-descending aortic bypass (ADAB) in such situations has not yet been fully discussed. Case report and literature review.
View Article and Find Full Text PDFHeart Rhythm O2
December 2024
Vanderbilt Heart and Vascular Institute, Vanderbilt University Medical Center, Nashville, Tennessee.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!