A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Label-free and selective sensing of uric acid with gold nanoclusters as optical probe. | LitMetric

Label-free and selective sensing of uric acid with gold nanoclusters as optical probe.

Talanta

Key Laboratory on Luminescence and Real-Time Analytical Chemistry (Southwest University), Ministry of Education, College of Pharmaceutical Sciences, Southwest University, Chongqing 400715, China. Electronic address:

Published: May 2016

Clinically, the amount of uric acid (UA) in biological fluids is closely related to some diseases such as hyperuricemia and gout, thus it is of great significance to sense UA in clinical samples. In this work, red gold nanoclusters (AuNCs) with relatively high fluorescence quantum yield and strong fluorescence emission were facilely available using bovine serum albumin (BSA) as template. The fluorescence of BSA-protected AuNCs can be sensitively quenched by H2O2, which is further capable of sensing UA through the specific catalytic oxidation with uricase, since it generates stoichiometric quantity of H2O2 by-product. The proposed assay allows for the selective detection of UA in the range of 10-800 μM with a detection limit of 6.6 μM, which is applicable to sense UA in clinical samples with satisfactory results, suggesting its great potential for diagnostic purposes.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.talanta.2016.01.018DOI Listing

Publication Analysis

Top Keywords

uric acid
8
gold nanoclusters
8
sense clinical
8
clinical samples
8
label-free selective
4
selective sensing
4
sensing uric
4
acid gold
4
nanoclusters optical
4
optical probe
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!