We conducted an animal experiment to investigate the effects of mechanical trauma to the round window with the placement of a model electrode inserted into the scala tympani on the cochlear reserve, and to determine the efficacy of topical steroids in preventing hearing loss in such a situation. Our subjects included 21 male Wistar albino rats that were assigned into three groups of 7 each. In all three groups, an initial mechanical injury to the round window was created. At that point, group 1 received no further treatment, group 2 received a dexamethasone injection into the cochlea, and group 3 underwent implantation of a multichannel cochlear implant guide followed by dexamethasone administration. After a few minutes, the round window opening was obliterated with muscle, and the incision was sutured with 4-0 Vicryl Rapide polyglactin in all 3 groups. Distortion-product otoacoustic emissions were obtained before and immediately after the surgical injury, and again on postoperative day 7. Mean signal/noise ratios (S/Ns) obtained at 2, 3, and 4 kHz were calculated, and datasets were compared with nonparametric statistical tests. We found that the early postoperative mean S/N values were significantly lower than the preoperative values in groups 1 and 2, but there was no difference between the mean preoperative values and those obtained on postoperative day 7 in those two groups. In group 3, there were statistically significant differences among the mean preoperative, early postoperative, and postoperative day 7 S/N values. We observed that an electrode insertion into the cochlea via the round window subsequent to mechanical trauma seemed to cause a progressive hearing loss. Therefore, we conclude that special care must be taken to avoid injury to the round window membrane during placement of a cochlear implant electrode, as well as during surgery for chronic otitis media.
Download full-text PDF |
Source |
---|
Otol Neurotol
January 2025
Department of Otolaryngology, Hualien Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation, Hualien, Taiwan.
Hypothesis: Extracochlear electric-acoustic stimulation (EAS) between the round window membrane and the basal part of the cochlear bone exhibits distinct auditory brainstem response (ABR) characteristics.
Background: The use of EAS in individuals with residual hearing is becoming increasingly common in clinical settings. Ongoing research has explored the characteristics of EAS-induced responses in hearing cochleae.
Front Neurol
December 2024
Department of Otorhinolaryngology, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
Objectives: Multiple studies have described the onset and variable incidence of postoperative acute vertigo following cochlear implant (CI) surgery. However, postoperative imaging has not yet been specifically evaluated with special focus on vertigo. The aim of this study is to assess the incidence and causes of new-onset, acute postoperative vertigo following CI surgery using cone beam computed tomography (CBCT).
View Article and Find Full Text PDFTissue Cell
December 2024
ENT Department, Faculty of Medicine, Suez Canal University, Ismailia, Egypt. Electronic address:
Background: Sensorineural hearing loss (SNHL) is the most common sensory deficit worldwide. Current solutions for SNHL, including hearing aids, cochlear implants, and hearing assistive devices, do not provide consistent results and fail to address the underlying pathology of hair cell and ganglion cell damage. Stem cell therapy is a cornerstone in regenerative medicine.
View Article and Find Full Text PDFEur Arch Otorhinolaryngol
January 2025
Department of Radiology, Istanbul Training and Research Hospital, University of Health Sciences, Istanbul, Turkey.
Purpose: Cochlear implantation (CI) surgery is essential for restoring hearing in individuals with severe sensorineural hearing loss. Accurate placement of the electrode within the cochlea is essential for successful auditory outcomes and minimizing complications. This study aims to analyze the relationship between the round window niche (RWN) alignment, its visibility during surgery, and the impact on surgical techniques and outcomes.
View Article and Find Full Text PDFEur Radiol Exp
January 2025
Guilloz Imaging Department, Central Hospital, University Hospital Center of Nancy, 29 Avenue du Marechal de Lattre de Tassigny, 54000, Nancy, France.
Background: We evaluated the accuracy of magnetic resonance imaging (MRI) computed tomography (CT)-like sequences compared to normal-resolution CT (NR-CT) and super-high-resolution CT (SHR-CT) for planning of cochlear implantation.
Methods: Six cadaveric temporal bone specimens were used. 3-T MRI scans were performed using radial volumetric interpolated breath-hold (STARVIBE), pointwise-encoding time reduction with radial acquisition (PETRA), and ultrashort time of echo (UTE) sequences.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!