Purpose: To evaluate the accuracy and utility of a new image overlay system using a tablet PC for patients undergoing peripheral arterial reconstruction.

Methods: Eleven limbs treated with distal bypass surgery were studied. Three-dimensional images obtained by processing a preoperative contrast-enhanced computed tomography scan were superimposed onto the back-camera images of a tablet PC. We used this system to pinpoint a planned distal anastomotic site preoperatively and to make a precise incision directly above it during surgery. We used a branch artery near the distal anastomotic site as a reference point and the accuracy of the system was validated by comparing its results with the intraoperative findings. The precision of the system was also compared with that of a preoperative ultrasonographic examination.

Results: Both the image overlay system and ultrasonography (US) accurately identified the target branch artery in all except one limb. In that limb, which had a very small reference branch artery, preoperative US wrongly identified another branch, whereas the image overlay system located the target branch with an error of 10 mm.

Conclusions: Our image overlay system was easy to use and allowed us to precisely identify a target artery preoperatively. Therefore, this system could be helpful for pinpointing the most accurate incision site during surgery.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00595-016-1326-4DOI Listing

Publication Analysis

Top Keywords

image overlay
20
overlay system
20
branch artery
12
system
9
system tablet
8
peripheral arterial
8
distal anastomotic
8
anastomotic site
8
target branch
8
overlay
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!