The aims of this study were to characterize different BS/PLGA composites for their physicochemical and morphological characteristics and evaluate the in vitro and in vivo biological performance. The physicochemical and morphological modifications were analyzed by pH, mass loss, XRD, setting time, and SEM. For in vitro analysis, the osteoblast and fibroblast viability was evaluated. For in vivo evaluations, histopathology and immunohistochemistry were performed in a tibial defect in rats. After incubation, all composites presented lower values in pH and mass loss over time. Moreover, XRD and SEM analysis confirmed that the composites degraded over time. Additionally, pore formation was observed by SEM analysis after incubation mainly in BS/PLGA groups. BS/PLGA showed significantly increased in osteoblast viability 24 h. Moreover, BS/PLGA composites demonstrated an increase in fibroblast viability in all periods analyzed when compared to BS. In the in vivo study, after 2 and 6 weeks of implantation of biomaterials, histopathological findings revealed that the BS/PLGA composites degrades over time, mainly at periphery. Moreover, can be observed the presence of granulation tissue, bone formation, Runx-2, and RANKL immunoexpression in all groups. In conclusion, BS/PLGA composites present appropriate physicochemical characteristics, stimulate the cellular viability, and enhance the bone repair in vivo. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 1063-1074, 2017.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/jbm.b.33654 | DOI Listing |
J Photochem Photobiol B
August 2017
Department of Biosciences, Federal University of São Paulo (UNIFESP), Santos, SP, Brazil.
The main purpose of the present work was to evaluate if low laser level therapy (LLLT) can improve the effects of Biosilicate®/PLGA (BS/PLGA) composites on cell viability and bone consolidation using a tibial defects of rats. The composites were characterized by scanning electron microscope (SEM) and reflection Fourier transform infrared spectrometer (FTIR). For the in vitro study, fibroblast and osteoblast cells were seeded in the extract of the composites irradiated or not with LLLT (Ga-Al-As, 808nm, 10J/cm) to assess cell viability after 24, 48 and 72h.
View Article and Find Full Text PDFJ Biomed Mater Res B Appl Biomater
July 2017
Department of Biosciences, Federal University of São Paulo (UNIFESP), Santos, São Paulo, Brazil.
The aims of this study were to characterize different BS/PLGA composites for their physicochemical and morphological characteristics and evaluate the in vitro and in vivo biological performance. The physicochemical and morphological modifications were analyzed by pH, mass loss, XRD, setting time, and SEM. For in vitro analysis, the osteoblast and fibroblast viability was evaluated.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!