Conclusion Bonebridge (BB) and Sophono (SP) devices improved hearing; with the BB implant showing a better performance at medium and high frequencies. Furthermore, the BB, as an active implant, showed higher functional gain and increased time of use, when compared to the SP, a passive system. Objectives This study aims to compare surgical and audiological outcomes of SP and BB devices in order to assess and further differentiate the indication criteria. Methods Fourteen patients with conductive and mixed hearing loss were evaluated pre- and post-operatively (BB or SP) (period 2013-2014). Age, gender, surgical history, cause and type of hearing loss, implant use per day, levels of bone and air conduction, and functional gain were recorded. Data was analysed by Wilcoxon singed-rank and Wilcoxon rank-sum tests. Results Fourteen patients (BB; n = 10 and SP; n = 4) with an average age = 25.42 years (CI95 = 12.41-38.43) were evaluated. The gender relation was equal (1:1), with pre-implantation osseous thresholds of 20.42 dB (CI95 = 11.15-29.69), and pre-implantation aerial thresholds of 70.83 dB (CI95 = 62.52-79.14). The SP wearing time was significantly lower than that of the BB (SP = 7-10 h/day, BB = 8-12 h/day; p = 0.0323). The functional gain did not differ significantly between the two devices (BB = 40.00 ± 13.19 dB, SP = 34.06 ± 15.63 dB; p = 0.3434), but a significant improvement from pre- to post-implantation was observed (p < 0.05). BB and SP decreased auditory thresholds at 1 and 2 kHz (< 0.01), respectively. The BB even significantly decreased thresholds at 0.5 kHz (p = 0.0140) and 4 kHz (p < 0.0001). No relevant surgical complications were found.

Download full-text PDF

Source
http://dx.doi.org/10.3109/00016489.2016.1143119DOI Listing

Publication Analysis

Top Keywords

functional gain
12
fourteen patients
8
hearing loss
8
comparative outcomes
4
outcomes active
4
active passive
4
hearing
4
passive hearing
4
devices
4
hearing devices
4

Similar Publications

Malignant gliomas are heterogeneous tumors, mostly incurable, arising in the central nervous system (CNS) driven by genetic, epigenetic, and metabolic aberrations. Mutations in isocitrate dehydrogenase (IDH1/2) enzymes are predominantly found in low-grade gliomas and secondary high-grade gliomas, with IDH1 mutations being more prevalent. Mutant-IDH1/2 confers a gain-of-function activity that favors the conversion of a-ketoglutarate (α-KG) to the oncometabolite 2-hydroxyglutarate (2-HG), resulting in an aberrant hypermethylation phenotype.

View Article and Find Full Text PDF

The diversity and heterogeneity of biomarkers has made the development of general methods for single-step quantification of analytes difficult. For individual biomarkers, electrochemical methods that detect a conformational change in an affinity binder upon analyte binding have shown promise. However, because the conformational change must operate within a nanometer-scale working distance, an entirely new sensor, with a unique conformational change, must be developed for each analyte.

View Article and Find Full Text PDF

Micro/nanoscale 3D bioelectrodes gain increasing interest for electrophysiological recording of electroactive cells. Although 3D printing has shown promise to flexibly fabricate 3D bioelectronics compared with conventional microfabrication, relatively-low resolution limits the printed bioelectrode for high-quality signal monitoring. Here, a novel multi-material electrohydrodynamic printing (EHDP) strategy is proposed to fabricate bioelectronics with sub-microscale 3D gold pillars for in vitro electrophysiological recordings.

View Article and Find Full Text PDF

Rationale: Peliosis hepatis (PH) is a rare disease with few clinical reports and complex etiology. However, there have been no reports of hyperprolactinemia (HPRL) leading to PH at present. This paper, through case reports, expands the understanding of the etiology of PH and the pathological damage effect of prolactin (PRL).

View Article and Find Full Text PDF

Pupil responses are commonly used to provide insight into visual perception, autonomic control, cognition, and various brain disorders. However, making inferences from pupil data can be complicated by nonlinearities in pupil dynamics and variability within and across individuals, which challenge the assumptions of linearity or group-level homogeneity required for common analysis methods. In this study, we evaluated luminance evoked pupil dynamics in young healthy adults (n = 10, M:F = 5:5, ages 19-25 years) by identifying nonlinearities, variability, and conserved relationships across individuals to improve the ability to make inferences from pupil data.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!