AI Article Synopsis

  • Various types of retrievable vena cava filters (VCFs) are used in patients, but many remain in place despite being designed for removal; this study examines their placement and retrieval.
  • In a 5-year period at Rabin Medical Center, 306 VCFs were inserted, with only 31 (10.1%) being successfully retrieved, mostly due to venous thromboembolic events and contraindications to anticoagulants.
  • The average indwelling time for the filters was about 3.5 months, and overall results showed that all three filter types were safe to use, with no significant differences in retrieval rates or complications among them.

Article Abstract

Background: Various vena cava filters (VCF) are designed with the ability to be retrieved percutaneously. Yet, despite this option most of them remain in the inferior vena cava (IVC).

Objectives: To report our experience in the placement and retrieval of three different types of VCFs, and to compare the indications for their insertion and retrieval as reported in the literature.

Methods: During a 5 year period three types of retrievable VCF (ALN, OptEase, and Celect) were inserted in 306 patients at the Rabin Medical Center (Beilinson and Hasharon hospitals). Indications, retrieval rates, median time to retrieval, success and complication rates were viewed and assessed in the three groups of filter types and were compared with the data of similar studies in the literature.

Results: Of the 306 VCFs inserted, 31 (10.1%) were retrieved with equal distribution in the three groups. In most patients the reason for filter insertion was venous thromboembolic events (VTE) and contraindications to anticoagulant therapy. Mean age was 68.38 ± 17.5 years (range 18-99) and was noted to be significantly higher compared to similar studies (53-56 years) (P < 0.0001). Multi-trauma patients were significantly older (71.11 ± 14.99 years) than post-pulmonary embolism patients (48.03 ± 20.98 years, P < 0.0001) and patients with preventive indication (26.00 ± 11.31, P < 0.0001). The mean indwelling time was 100.6 ± 103.399 days. Our results are comparable with the results of other studies, and there was no difference in percentage of retrieval or complications between patients in each of the three groups.

Conclusions: In 1 of 10 patients filters should be removed after an average of 3.5 months. All three IVC filter types used are safe to insert and retrieve.

Download full-text PDF

Source

Publication Analysis

Top Keywords

vena cava
12
inferior vena
8
cava filters
8
indwelling time
8
success complication
8
complication rates
8
three types
8
three groups
8
filter types
8
years 00001
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!