Purpose: The incidence of avascular necrosis (AVN) following reconstructive hip surgery in cerebral palsy (CP) ranges from 0 to 69 % in the current literature. The purpose of this study was to determine the inter- and intra-observer reliability of radiographically diagnosing AVN in children with CP after hip surgery.
Methods: A retrospective review of 65 children with CP who had reconstructive hip surgery between 2009 and 2012 at BC Children's Hospital was completed. Anterior-posterior and lateral radiographs were presented to four pediatric orthopaedic surgeons over two rounds. Surgeons were asked to review the set of unidentified radiographs and comment 'yes' or 'no' for the presence of AVN. Two weeks later the same set of radiographs was sent in a different order and the surgeons were again asked to comment on AVN. Inter- and intra-observer reliability was determined using kappa statistics.
Results: The intra-observer reliability ranged from 0.65 to 0.88 with an average score of 0.76. Inter-observer reliability showed greater variability, ranging from 0.41 to 0.77 with an average score of 0.56 across all surgeons.
Conclusions: Although the intra-rater reliability produced a strength of "good" and the inter-rater reliability a strength of "moderate" agreement, the variability within these scores is clinically important as it demonstrates the difficulty in identifying AVN. This may explain the variability in AVN that is reported in the literature. The need for further education and research in the diagnosis of AVN in children with CP who have undergone reconstructive hip surgery is clinically necessary.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4837166 | PMC |
http://dx.doi.org/10.1007/s11832-016-0723-y | DOI Listing |
Eur Spine J
January 2025
Department of Orthopaedic Surgery, Medical College of Wisconsin, Milwaukee, USA.
Purpose: No studies have explored the reliability of the Rigo classification system using surface topography (ST), which would allow optimization without radiation exposure. This study aims to measure and compare the intra- and inter-observer reliability (Kappa values) and accuracy of the Rigo system between ST and X-ray for overall types and subtypes.
Methods: X-ray and ST images of 31 adolescent idiopathic scoliosis patients were selected.
J Perinat Med
January 2025
Perinatal Imaging Research Group, School of Clinical Medicine, Discipline of Women's Health, Faculty of Medicine, University of New South Wales, Sydney, NSW, Australia.
Objectives: Multiple techniques have been proposed for functional fetal cardiology, including pulsed-wave (PW) and tissue Doppler imaging (TDI), Myocardial Performance Index (MPI), annular plane systolic excursion (TAPSE/MAPSE) and spatiotemporal image correlation (STIC). We aimed to compare these techniques' achievability and reproducibility to determine their clinical utility for each cardiac side.
Methods: Uncomplicated pregnancies from 22 to 39 weeks were recruited and images and volumes stored for offline analysis.
BMC Oral Health
January 2025
Department of Orthodontics, Case Western Reserve University School of Dental Medicine, Cleveland, OH, 44106, USA.
Background: The aim of this study was to evaluate the correlation of the volume and minimum axial area (MAA) measurements between different upper and lower boundaries used for oropharyngeal airway assessment.
Methods: Cone Beam Computed Tomography (CBCT) scans of 49 subjects taken for pre-orthognathic surgical planning were obtained retrospectively from the archives (n = 49; 32 females, 17 males; mean age = 20.9 ± 5.
J Dent
December 2024
OMFS-IMPATH Research Group, Department of Imaging and Pathology, Faculty of Medicine, KU Leuven, Leuven, Belgium; Department of Dental Medicine, Karolinska Institute, Stockholm, Sweden. Electronic address:
BMC Oral Health
December 2024
Department of Oral Surgery, Universidad de Salamanca, Salamanca, 37007, Spain.
Background: Knowing the available dental space in a patient is crucial for orthodontists to develop a good treatment plan.
Objectives: To compare and evaluate the reliability, reproducibility, and accuracy of three measurement methods on models: conventional, mobile app, and digital software.
Materials And Methods: Maxillary and mandibular dental plaster models of 20 subjects with permanent dentition were analyzed.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!