A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Whirling agitated single drop microextraction technique for the simultaneous analysis of Paraquat and Maneb in tissue samples of treated mice. | LitMetric

A new microextraction technique, whirling agitated single drop microextraction, has been proposed for the simultaneous analysis of Paraquat and Maneb in tissue samples before liquid chromatography with tandem mass spectrometry. This technique is based on the idea that the escalatory motion of the sample solution along with the extraction solvent increases the movement of molecules into the extraction solvent. In this technique, a simple handheld rotator was utilized to rapidly agitate the biphasic extraction system for the instantaneous extraction of targeted analytes. After extraction, the extracted phase was directly solidified by cooling in crushed ice and easily collected using a micro-spatula. The method showed good performance by achieving sensitive detection limits at 4.81 ng g(-1) (Paraquat) and 9.12 ng g(-1) (Maneb). Mean recoveries and enrichment factors were obtained >91.21% and up to 114 that ensured the preconcentration capacity of the method. The method precision was verified by evaluating intraday variation (n = 10) ≤4.57 (Paraquat) and ≤4.68 (Maneb) in terms of percent relative standard deviation. Additionally, method efficacy was assured by obtaining very little matrix interferences (≤3.11%). Moreover, the method suitability was also checked with its application on tissue samples of intraperitoneally treated mice with Paraquat and Maneb.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jssc.201501048DOI Listing

Publication Analysis

Top Keywords

paraquat maneb
12
tissue samples
12
whirling agitated
8
agitated single
8
single drop
8
drop microextraction
8
microextraction technique
8
simultaneous analysis
8
analysis paraquat
8
maneb tissue
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!