[A prospective study to compare the efficiency of oocyte vitrification using closed or open devices].

Gynecol Obstet Fertil

Service d'histologie-embryologie-cytogénétique-biologie de la reproduction-CECOS, centre hospitalier universitaire Jean-Verdier, avenue du 14-Juillet, 93140 Bondy, France; UFR SMBH, université Paris 13, Sorbonne Paris cité, 93000 Bobigny, France. Electronic address:

Published: May 2016

Objectives: Oocyte vitrification using an open device is thought to be a source of microbiological and chemical contaminations that can be avoided using a closed device. The principal purpose of this study was to compare the two vitrification protocols: closed and open system. The secondary aim was to study the effects of the storage in the vapor phase of nitrogen (VPN) on oocytes vitrified using an open system and to compare it to those of a storage in liquid nitrogen (LN).

Methods: Forty-four patients have been included in our study between November 2014 and May 2015. Two hundred and fourteen oocytes have been vitrified at germinal vesicle (GV), metaphase I (0PB) and metaphase II (1PB) stages. We vitrified 96 oocytes (59 GV/37 0PB) using a closed vitrification device and 118 oocytes (57 GV/31 0PB/30 1PB) using an open device. The vitrified oocytes were then stored either in LN or in VPN. The main outcome measures were the survival rate after warming (SR), meiosis resumption rate (MRR) and maturation rate (MR).

Results: The global post-thaw SR was significantly higher for oocytes vitrified using an open system (93.2%) compared to those vitrified using a closed one (64.5%; P<0.001). On the contrary, there was no significant difference in terms of global MRR and MR (82.1% vs. 87.5% and 60.7% vs. 61.2% using closed and open system respectively). The SR, MRR and the MR were not significantly different when vitrified oocytes were stored in VPN or LN (91.6, 83.8, 64.5% vs. 93.9, 89.8, 59.1% respectively).

Conclusion: Taking into account the limits of our protocol, the open vitrification system remains the more efficient system. The use of sterile liquid nitrogen for oocyte vitrification and the subsequent storage in vapor phase of nitrogen could minimize the hypothetical risks of biological and chemical contaminations.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.gyobfe.2016.02.003DOI Listing

Publication Analysis

Top Keywords

open system
12
oocytes vitrified
12
study compare
8
oocyte vitrification
8
closed open
8
open device
8
vitrified open
8
open
6
vitrified
6
closed
5

Similar Publications

While maternal mortality decreased during the Millennium Development Goals era, it remains unacceptably high, with stagnation in reductions possible due to shocks such as COVID-19. Most women in low- and middle-income countries already receive antenatal care and over half give birth in health facilities. In cities, use of health facilities for childbirth is near universal (>90%).

View Article and Find Full Text PDF

Retrospective descriptive report comparing access systems to refine intravenous self-administration in rats.

Lab Anim

January 2025

Department of Population Health Sciences, Section Animals in Science and Society, Faculty of Veterinary Medicine, Utrecht University, the Netherlands.

For operant self-administration, permanent intravenous cannulas need to remain open and operational for months without infections or blockages. Here, we report retrospectively on our experiences and observations using different access systems during three studies. We identified a refined method for vena jugularis cannulation that is a vast improvement for the animals, biotechnicians and researchers.

View Article and Find Full Text PDF

Stressors contributing to burnout among acute care and trauma surgery care teams: a systems-analysis approach.

Trauma Surg Acute Care Open

January 2025

Division of Healthcare Engineering, Department of Radiation Oncology, The University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, USA.

Background: Burnout negatively impacts healthcare professionals' well-being, leading to an increased risk of human errors and patient harm. There are limited assessments of burnout and associated stressors among acute care and trauma surgery teams.

Methods: Acute care and trauma surgery team members at a US academic medical center were administered a survey that included a 2-item Maslach Burnout Inventory and 21 workplace stressors based on the National Academy of Medicine's systems model of clinician burnout and professional well-being.

View Article and Find Full Text PDF

Background: Operative mortality for high-grade liver injury (HGLI) remains 42% to 66%, with near-universal mortality after retrohepatic caval injury. The objective of this study was to evaluate mortality and complications of operative and nonoperative management (OM and NOM) of HGLI at our institution, characterized by a trauma surgery-liver surgery collaborative approach to trauma care.

Methods: This was an observational cohort study of adult patients (age ≥16) with HGLI (The American Association for Surgery of Trauma (AAST) grades IV and V) admitted to an urban level I trauma center from January 2010 to November 2021.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!