Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 143
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 143
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 209
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3098
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Severity: Warning
Message: Attempt to read property "Count" on bool
Filename: helpers/my_audit_helper.php
Line Number: 3100
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3100
Function: _error_handler
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Carotid intima-media thickness (cIMT) is a surrogate marker of early atherosclerotic changes in children. cIMT-studies are hard to compare, due to variations in ultrasound protocols, especially regarding the common carotid artery (CCA) segment measured in relation to the bulb. This study's purpose was therefore to compare two distinct CCA segments in children, to see if cIMT values differ substantially according to the site of measurement. cIMT was assessed after power calculation in 30 children (15 girls) aged 8-17, using B-Mode ultrasound (5-13 MHz) at two CCA locations. The first measurement was performed over a distance of 1 cm immediately after the bulb (A), the second 1cm proximal the bulb (B) over the same distance of 1cm length. Means of end-diastolic far wall cIMT were compared between measurement A and B. cIMT in 30 participants was 0.51±0.06 mm for measurement A and 0.51±0.05 mm for measurement B. Results did not differ significantly (p = .947) over a distance of 2 cm after the bulb. According to our results, studies measuring CCA IMT within the first 2 cm, either close to the bulb or further proximal, can be compared. This will improve interpretation of data and application of reference values.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4788416 | PMC |
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0149057 | PLOS |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!