Early white matter involvement in an infant carrying a novel mutation in ACOX1.

Eur J Paediatr Neurol

Department of Neuroscience, Biomedicine, Movement-Neurology (Child Neurology and Psychiatry), University of Verona, Italy. Electronic address:

Published: May 2016

We describe the clinical findings and MRI features observed in a child who presented a two-step disease course: he was hypotonic at birth and soon afterwards developed seizures, which were partially responsive to treatment; he subsequently showed developmental delay and a progressive neurological deterioration with the onset of severe seizures at around three years of age. Head MRI at age 20 days was unremarkable, whereas at 25 months it showed bilateral hyperintensity of the deep cerebellar nuclei; five months later, the signal hyperintensity was also present in the cerebellar white matter and ventral pontine fibre tracts. Molecular analysis revealed a novel ACOX1 mutation, predicting a largely truncated protein. The white matter involvement, which followed an ascending trajectory from cerebellar and brainstem structures to the cerebral hemispheres, seemed to originate from the perinuclear white matter of the deep cerebellar nuclei.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ejpn.2016.02.007DOI Listing

Publication Analysis

Top Keywords

white matter
16
matter involvement
8
deep cerebellar
8
cerebellar nuclei
8
early white
4
matter
4
involvement infant
4
infant carrying
4
carrying novel
4
novel mutation
4

Similar Publications

A comprehensive study of the angular distributions in the bottom-baryon decays Λ_{b}^{0}→Λ_{c}^{+}h^{-}(h=π,K), followed by Λ_{c}^{+}→Λh^{+} with Λ→pπ^{-} or Λ_{c}^{+}→pK_{S}^{0} decays, is performed using a data sample of proton-proton collisions corresponding to an integrated luminosity of 9  fb^{-1} collected by the LHCb experiment at center-of-mass energies of 7, 8, and 13 TeV. The decay parameters and the associated charge-parity (CP) asymmetries are measured, with no significant CP violation observed. For the first time, the Λ_{b}^{0}→Λ_{c}^{+}h^{-} decay parameters are measured.

View Article and Find Full Text PDF

Late-Onset Krabbe Disease: Case Report of Two Patients in a Chinese Family and Literature Review.

Mol Genet Genomic Med

February 2025

Department of Orthopeadic Surgery, Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, Guangzhou, People's Republic of China.

Background: Krabbe disease (KD; globoid cell leucodystrophy) is a rare autosomal recessive lipid storage disorder that affects the white matter of the peripheral and central nervous. Late-onset KD is less frequently diagnosed and often presents with milder symptoms, making accurate diagnosis challenging, especially when distinguishing it from peripheral neuropathy. In this report, we present two cases of late-onset KD in a Chinese family.

View Article and Find Full Text PDF

White Matter Injury in Central Nervous System Disorders.

Neuropsychiatr Dis Treat

January 2025

Department of Rehabilitation Medicine, The Affiliated Taian City Central Hospital of Qingdao University, Taian, 271000, People's Republic of China.

As the aging process accelerates and living conditions improve, central nervous system (CNS) diseases have become a major public health problem. Diseases of the CNS cause not only gray matter damage, which is primarily characterized by the loss of neurons, but also white matter damage. However, most previous studies have focused on grey matter injury (GMI), with fewer studies on white matter injury (WMI).

View Article and Find Full Text PDF

CADASIL (Cerebral Autosomal Dominant Arteriopathy with Subcortical Infarcts and Leukoencephalopathy) is a hereditary small vessel disease caused by mutations in the NOTCH3 gene, characterized by recurrent strokes, cognitive decline, and psychiatric symptoms. This report presents a novel NOTCH3 c.1564 T > A (p.

View Article and Find Full Text PDF

Purpose: The purpose of this work was to evaluate the image quality of a commercial CT scanner equipped with a novel detector and filtration technology called PureVision Optics (PVO).

Methods: CT number, noise, contrast-to-noise ratio (CNR), modulation transfer function (MTF), and noise power spectrum (NPS) were assessed using the ACR CT Accreditation phantom scanned with various acquisitions at 80 kV, 100 kV, 120 kV, and 135 kV, each with multiple CTDIvol values of 20 mGy, 40 mGy, and 65 mGy. Artifacts were evaluated in an anthropomorphic head phantom, a cadaver head, and in patient studies.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!