A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

An efficient technique for estimating the two-dimensional temperature distributions around multiple cryo-surgical probes based on combining contributions of unit circles. | LitMetric

This study presents an efficient, fast and accurate method for estimating the two-dimensional temperature distributions around multiple cryo-surgical probes. The identical probes are inserted into the same depth and are operated simultaneously and uniformly. The first step in this method involves numerical derivation of the temporal performance data of a single probe, embedded in a semi-infinite, tissue-like medium. The results of this derivation are approximated by algebraic expressions that form the basis for computing the temperature distributions of multiple embedded probes by combining the data of a single probe. Comparison of isothermal contours derived by this method to those computed numerically for a variety of geometrical cases, up to 15 inserted probes and 2-10 min times of operation, yielded excellent results. Since this technique obviates the solution of the differential equations of multiple probes, the computational time required for a particular case is several orders of magnitude shorter than that needed for obtaining the full numerical solution. Blood perfusion and metabolic heat generation rates are demonstrated to inhibit the advancement of isothermal fronts. Application of this method will significantly shorten computational times without compromising the accuracy of the results. It may also facilitate expeditious consideration of the advantages of different modes of operation and the number of inserted probes at the early design stage.

Download full-text PDF

Source
http://dx.doi.org/10.1080/10255842.2016.1154546DOI Listing

Publication Analysis

Top Keywords

temperature distributions
12
distributions multiple
12
estimating two-dimensional
8
two-dimensional temperature
8
multiple cryo-surgical
8
cryo-surgical probes
8
data single
8
single probe
8
inserted probes
8
probes
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!