Introduction: Variation in clinical practice resulting from the absence of evidence-based treatment protocols has negative implications on both the cost and the quality of medical care. The objective of this study was to assess whether a standard of care for the treatment of extra-articular nondisplaced distal radius fracture has developed despite the lack of a conclusive recommendation from the American Academy of Orthopaedic Surgeons.
Methods: A case-vignette survey was conducted. Treatment type and duration of casting selections were analyzed. The cost implications of responses were assessed. Participants were practicing orthopedists primarily in the mid-Atlantic region of the United States. Orthopedists (n = 494) were recruited via E-mail and at the American Academy of Orthopaedic Surgeons Annual Meeting held in Chicago in March 2013. Inclusion criteria required that participants be graduates of an accredited medical school and be practicing orthopedists at the time of survey distribution. The main outcome measure was surgical or nonsurgical intervention.
Results: Nonsurgical treatment was selected by 60% of respondents, with surgery preferred by 37%. Duration of casting responses varied from 2 to 12 weeks. Among nonsurgical responses, 69% indicated 6 weeks as their preferred duration of casting (95% confidence interval, 64.9-73.1%). Surgery imposes a 76% greater total cost to society than nonsurgical treatments.
Conclusions: Our findings suggest the absence of a consensus strategy for the treatment of extra-articular nondisplaced distal radius fractures. Implications of variance in treatment on cost and quality support the need for established, evidence-based guidelines or further clinical trials to assist in the management of this common fracture.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.3122/jabfm.2016.02.150233 | DOI Listing |
Patient Saf Surg
January 2025
Department of Trauma, University Hospital Zurich, Raemistrasse 100, Zurich, 8091, Switzerland.
Introduction: Regional anesthesia increases in popularity in orthopaedic surgery. It is usually applied in elective surgeries of the extremities. The aim of this study was to assess indication of the use of general anesthesia in the surgical treatment of distal radius fractures.
View Article and Find Full Text PDFJBJS Case Connect
January 2025
Department of Orthopaedic Surgery, University of Tennessee Health Science Center College of Medicine Chattanooga, Chattanooga, Tennessee.
Case: A 41-year old man fell from height sustaining displaced radial shaft and ulnar styloid fractures underwent open reduction internal fixation of the radius with early recognition of a radiocapitellar dislocation and longitudinal forearm instability in the early postoperative period. Revision surgery was performed 13 days postoperatively involving annular ligament reconstruction, elbow spanning external fixation, and distal radioulnar joint stabilization. Favorable functional and radiographic outcomes are shown at 1-year follow-up.
View Article and Find Full Text PDFJ Hand Surg Eur Vol
January 2025
Royal United Hospital, Combe Park, Bath, Avon, BA1 3NG, UK.
We report a series of 12 patients who developed early distal radioulnar joint subluxation after a distal radial fracture, not present on the initial radiographs. Early identification and management of this condition can give good clinical results. IV.
View Article and Find Full Text PDFJ Hand Surg Eur Vol
January 2025
Department of Orthopedics, E-Da Hospital, I-Shou University/School of Medicine, College of Medicine, I-Shou University, Kaohsiung, Taiwan.
Treatment of distal radial fractures that include small anterior rim fragments can be difficult. We retrospectively reviewed 19 patients in whom an anterior rim plate with locking screws was used. After a median follow-up of 18 months (range 6-32; interquartile range (IQR) 14, 26), the median wrist flexion and extension arc was 70° (range 50-80; IQR 60, 70), the median grip strength was 80% of the contralateral side (range 52-104; IQR 77, 88), the median visual analogue scale score for pain was 0 (range 0-5; IQR 0, 1), the median disabilities of the arm, shoulder and hand score was 2 (range 0-59; IQR 0, 11) and the median modified Mayo wrist score was 80 (range 35-100; IQR 75, 85).
View Article and Find Full Text PDFInt J Numer Method Biomed Eng
January 2025
Department of Mathematics, University of Trento, Trento, Italy.
The main objectives of this work are to validate a 1D-0D unsteady solver with a distributed stenosis model for the patient-specific estimation of resting haemodynamic indices and to assess the sensitivity of instantaneous wave-free ratio (iFR) predictions to uncertainties in input parameters. We considered 52 patients with stable coronary artery disease, for which 81 invasive iFR measurements were available. We validated the performance of our solver compared to 3D steady-state and transient results and invasive measurements.