Study Design: Controlled laboratory study.

Background: The hip abductor muscles are important hip joint stabilizers. Hip joint pain may alter muscle recruitment. Motion-mode (M-mode) ultrasound enables noninvasive measurements of the onset of deep and superficial muscle motion, which is associated with activation onset.

Objectives: To compare (1) the onset of superficial and deep gluteus medius and gluteus minimus muscle motion relative to the instant of peak ground reaction force and (2) the level of swing-phase muscle motion during step-down between subjects with chronic hip pain and controls using M-mode ultrasound.

Methods: Thirty-five subjects with anterior, nontraumatic hip pain for more than 6 months (mean ± SD age, 54 ± 9 years) and 35 controls (age, 57 ± 7 years) were scanned on the lateral hip of the leading leg during frontal step-down onto a force platform using M-mode ultrasound. Computerized motion detection with the Teager-Kaiser energy operator was applied on the gluteus minimus and the deep and superficial gluteus medius to determine the time lag between muscle motion onset and instant of peak ground reaction force and the level of gluteus minimus motion during the swing phase. Time lags and motion levels were averaged per subject, and t tests were used to determine between-group differences.

Results: In participants with hip pain, gluteus minimus motion onset was 103 milliseconds earlier (P = .002) and superficial gluteus medius motion was 70 milliseconds earlier (P = .047) than those in healthy control participants. The level of gluteus minimus swing-phase motion was higher with pain (P = .006).

Conclusion: Increased gluteus minimus motion during the swing phase and earlier gluteus minimus and superficial gluteus medius motion in individuals with hip pain suggest an overall increase of muscle activity, possibly a protective behavior.

Download full-text PDF

Source
http://dx.doi.org/10.2519/jospt.2016.6132DOI Listing

Publication Analysis

Top Keywords

gluteus minimus
32
hip pain
20
muscle motion
16
gluteus medius
16
m-mode ultrasound
12
gluteus
12
motion
12
superficial gluteus
12
minimus motion
12
hip
9

Similar Publications

Purpose: Identifying muscles linked to postoperative physical function can guide protocols to enhance early recovery following total hip arthroplasty (THA). This study aimed to evaluate the association of preoperative pelvic and thigh muscle volume and quality with early physical function after THA in patients with unilateral hip osteoarthritis (HOA).

Methods: Preoperative Computed tomography (CT) images of 61 patients (eight males and 53 females) with HOA were analyzed.

View Article and Find Full Text PDF

Degenerative gluteal tears associated with hip arthroplasty.

BMC Musculoskelet Disord

January 2025

Midlands Orthopaedics & Neurosurgery, 1910 Blanding Street, Columbia, SC, 29201, USA.

Background: Unrepaired chronic abductor tears may be a cause of residual pain and weakness after hip arthroplasty, but the current incidence is unclear.

Methods: From 1994 to 2009, the senior surgeon performed 1628 hip resurfacing and 864 total hip arthroplasties without identifying any gluteal tears. We recognized our first case of concomitant abductor tear during a hip resurfacing procedure in April 2009.

View Article and Find Full Text PDF

Background: The gluteus medius and minimus muscles play a critical role in hip biomechanics, however there is a paucity of literature examining the impact of preoperative gluteal pathology on outcomes following total hip arthroplasty (THA). This study compared pain, satisfaction, and functional outcomes among patients who had and did not have preoperative gluteal pathology after direct anterior (DA) THA.

Methods: Using an institutional total joint registry, patients undergoing DA THA for osteoarthritis between 2010 and 2022 were retrospectively reviewed.

View Article and Find Full Text PDF

Background: Total hip arthroplasty (THA) is generally considered a successful operation for patients with advanced hip arthritis. Hip abductor pathology can lead to diminished outcomes. The prevalence of hip abductor pathology in patients undergoing THA is not well described.

View Article and Find Full Text PDF

Background: Hip morphology variations, particularly in femoral neck shaft angle (NSA) and iliac wing width (IWW), have been associated with gluteal tendinopathy. However, the biomechanical implications of these morphological differences on gluteal muscle function are not well understood. This study investigates how NSA and IWW influence gluteal muscle forces, moment arms, and estimated tendon loads during walking, aiming to provide insights into the potential biomechanical pathways that may contribute to altered lateral hip loading patterns.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!