A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 144

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 144
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 212
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1002
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3142
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Direct screening of tobacco indicators in urine and saliva by Atmospheric Pressure Solid Analysis Probe coupled to quadrupole-time of flight mass spectrometry (ASAP-MS-Q-TOF-). | LitMetric

Direct screening of tobacco indicators in urine and saliva by Atmospheric Pressure Solid Analysis Probe coupled to quadrupole-time of flight mass spectrometry (ASAP-MS-Q-TOF-).

J Pharm Biomed Anal

Aragon Institute of Engineering Research (I3A), EINA, Department of Analytical Chemistry, University of Zaragoza, María de Luna 3, 50018 Zaragoza, Spain. Electronic address:

Published: May 2016

A new screening method has been explored for direct analysis of tobacco smoke biomarkers in biological matrices (i.e., saliva and urine). Single run analysis using Atmospheric pressure Solid Analysis Probe (ASAP) and high resolution mass spectrometry with quadrupole and time of flight detector has been applied directly to some biological samples (i.e., urine and saliva), providing a fast, efficient and sensitive method of identification. The method has been applied to saliva and urine samples from heavy tobacco smokers for exposure studies. Nicotine itself, nicotine metabolites (i.e., cotinine, trans-3'-hydroxycotinine, nicotine-N-glucuronide) and other related tobacco smoke toxic compounds (i.e., NNK 4-[methyl(nitroso)amino]-1-(3-pyridinyl)-1-butanone, anatabine) were found in the analyzed samples. The identification of compounds was confirmed by ultrahigh performance liquid chromatography with MS-triple quadrupole detector after sample treatment. Different temporal trends and biomarkers behavior have been found in time series related samples. Both methods are compared for screening of these biological matrices.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jpba.2016.02.033DOI Listing

Publication Analysis

Top Keywords

urine saliva
8
atmospheric pressure
8
pressure solid
8
solid analysis
8
analysis probe
8
mass spectrometry
8
tobacco smoke
8
biological matrices
8
saliva urine
8
direct screening
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!