Purpose: To evaluate the optical quality of 3 multifocal intraocular lenses (IOLs): the Mini Well Ready progressive multifocal aspheric IOL, the AT LISA trifocal diffractive IOL, and the Finevision full diffractive trifocal IOL.

Setting: University of Valencia, Valencia, Spain.

Design: Experimental study.

Methods: An instrument designed for measuring real-time modulation transfer function (MTF) and IOL power was used to measure the optical quality of each IOL for 3.0 mm and 4.5 mm apertures. This instrument measures both sagittal and tangential MTFs. The optical quality of each IOL was evaluated with the MTF, through-focus MTF, defocus tolerance, Strehl ratio MTF, and relative percentage of light in each focus. These metrics were evaluated at best focus for each IOL.

Results: Through-focus graphs corresponding to trifocal IOLs showed 3 mean peaks. Nevertheless, the progressive multifocal aspheric IOL showed 2 main areas, 1 corresponding to distance vision focus and the other including both intermediate and near vision foci.

Conclusions: The results obtained in the present study suggest that the progressive multifocal aspheric IOL might be considered for cataract surgery.

Financial Disclosure: None of the authors has a financial or proprietary interest in any method or material mentioned.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jcrs.2015.06.040DOI Listing

Publication Analysis

Top Keywords

optical quality
16
progressive multifocal
16
multifocal aspheric
12
aspheric iol
12
intraocular lenses
8
multifocal intraocular
8
quality iol
8
iol
7
multifocal
5
vitro optical
4

Similar Publications

Simulations of the Potential for Diffraction Enhanced Imaging at 8 keV using Polycapillary Optics.

Biomed Phys Eng Express

January 2025

Physics Department, University at Albany, 1400 Washington Ave, Albany, New York, 12222-0100, UNITED STATES.

Conventional x-ray radiography relies on attenuation differences in the object, which often results in poor contrast in soft tissues. X-ray phase imaging has the potential to produce higher contrast but can be difficult to utilize. Instead of grating-based techniques, analyzer-based imaging, also known as diffraction enhanced imaging (DEI), uses a monochromator crystal with an analyzer crystal after the object.

View Article and Find Full Text PDF

End-range movements are among the most demanding but least understood in the sport of tennis. Using male Hawk-Eye data from match-play during the 2021-2023 Australian Open tournaments, we evaluated the speed, deceleration, acceleration, and shot quality characteristics of these types of movement in men's Grand Slam tennis. Lateral end-range movements that incorporated a change of direction (CoD) were identified for analysis using k-means (end-range) and random forest (CoD) machine learning models.

View Article and Find Full Text PDF

Purpose: To evaluate the efficacy and safety of intense pulsed light (IPL) combined with meibomian gland expression (MGX) for the treatment of dry eye disease and meibomian gland dysfunction associated with chronic Stevens-Johnson syndrome and toxic epidermal necrolysis.

Methods: This prospective noncomparative interventional study included 29 patients (58 eyes) who underwent 3 sessions of IPL and MGX at 2-week intervals. Subjective symptoms (ocular surface disease index score) and objective dry eye tests: matrix metalloproteinase 9, tear meniscus height, bulbar redness score, tear film lipid layer thickness (LLT), Schirmer I test, conjunctival and corneal staining, meibomian gland loss, MGX score [meibomian gland score (MGS)], and tear break-up time were assessed at the baseline and after 4, 8, and 12 weeks.

View Article and Find Full Text PDF

Purpose: To report on optical coherence tomography angiography (OCTA) in patients with a type 1 Boston keratoprosthesis (KPro) and determine its feasibility through assessment of imaging artifacts.

Methods: KPro and non-KPro subjects were matched for age, gender, and glaucoma diagnosis. OCTA images of the peripapillary optic nerve were obtained, reviewed by 2 readers masked to the diagnosis for artifacts and usability, and used for microvascular measurements.

View Article and Find Full Text PDF

COVID-19 disease, triggered by SARS-CoV-2 virus infection, has led to more than 7.0 million deaths worldwide, with a significant fraction of recovered infected people reporting postviral symptoms. Smart surfaces functionalized with nanoparticles are a powerful tool to inactivate the virus and prevent the further spreading of the disease.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!