Biodegradable magnesium (Mg) alloys are the most promising candidates for osteosynthesis devices. However, their in vivo corrosion behaviour has not been fully elucidated. The aim of this study was to clarify the influence of the physiological environment surrounding Mg alloys on their corrosion behaviour. A Mg-1.0Al alloy with a fine-grained structure was formed into plates using titanium (Ti) as a control. These plates were implanted into the subperiosteum in the head, subcutaneous tissue of the back, and in the muscle of the femur of rats for 1, 2 and 4 weeks. The volumes of the remaining Mg alloy and of the insoluble salt deposition and gas cavities around the Mg alloy were determined by microtomography, and the volume losses were calculated. Then, the tissue response around the plates in each implantation site was examined histopathologically, and its relation to the respective volume loss was analyzed. These analyses determined that the Mg alloy was corroded fastest in the head, at an intermediate level in the back, and slowest in the femur. The insoluble salt deposition at the Mg alloy surface had no influence on the volume loss. Gas cavities formed around the Mg alloy at all implantation sites and decreased after 4 weeks. Histopathological examination revealed that the Mg alloy exhibited good biocompatibility, as was seen with Ti. In addition, vascularized fibrous capsules formed around the plates and became mature with time. Notably, the volume loss in the different anatomical locations correlated with capsule thickness. Together, our results suggest that, to facilitate the successful clinical application of Mg alloys, it will be necessary to further comprehend their interactions with specific in vivo environments.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1088/1748-6041/11/2/025001 | DOI Listing |
Int J Biol Macromol
December 2024
Department of Materials Science and Engineering, Faculty of Engineering & Technology, Tarbiat Modares Universirty, Tehran, Iran.
One of the most effective ways to solve the problems caused by the presence of steel implants in the body is to apply a coating to them. This study aims to develop and optimize composite coatings of magnesium oxide (MgO), 58S bioactive glass (BG), and N-carboxymethyl chitosan (N-CMC) on stainless steel (SS316L) substrates using the electrophoretic deposition (EPD) method. The synthesized materials were characterized using FTIR, XRD, and SEM to confirm their structure and morphology prior to coating.
View Article and Find Full Text PDFNanomaterials (Basel)
December 2024
College of Mechanical Science and Engineering, Northeast Petroleum University, Daqing 163318, China.
The corrosion resistance of nickel-titanium nitride (Ni/TiN) composites is significantly influenced by the operation parameters during the jet pulse electrodeposition (JPE) process. The effect of current density, jet rate, TiN concentration, and duty cycle impact on the anti-corrosion property of Ni/TiN composites were investigated and optimized using the response surface method (RSM). After the optimization of the operation parameters, the corrosion current of Ni/TiN composites decreased from 9.
View Article and Find Full Text PDFAngew Chem Int Ed Engl
December 2024
Chinese Academy of Sciences Dalian Institute of Chemical Physics, State Key Laboratory of Catalysis, CHINA.
Developing durably active catalysts to tackle harsh voltage polarization and seawater corrosion is pivotal for efficient solar-to-hydrogen (STH) conversion, yet remains a challenge. We report a durably active catalyst of NiCr-layered double hydroxide (RuldsNiCr-LDH) with highly exposed Ni-O-Ru units, in which low-loading Ru (0.32 wt%) is locked precisely at defect lattice site (Rulds) by Ni and Cr.
View Article and Find Full Text PDFLangmuir
December 2024
Department of Architectural Engineering, Hanyang University ERICA, 55 Hanyangdaehak-ro, Sangrok-gu, Ansan-si 15588, Gyeonggi-do, Republic of Korea.
Reliable corrosion inhibition systems are crucial for extending the lifespan of industrial metal structures. Quinolines, with their high adsorption capacity and protective efficiency, are promising next-generation inhibitors. However, the impact of substitutions on their coordination with iron surfaces requires deeper understanding.
View Article and Find Full Text PDFACS Nanosci Au
December 2024
State Key Laboratory of Physical Chemistry of Solid Surfaces, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China.
Acidic oxygen evolution reaction (OER) has long been the bottleneck of proton exchange membrane water electrolysis. Ru- and Ir-based oxides are currently state-of-the-art electrocatalysts for acidic OER, but their high cost limits their widespread application. CoO is a promising alternative, yet the performance requires further improvement.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!