The first step for neuroimaging data analysis: DICOM to NIfTI conversion.

J Neurosci Methods

McCausland Center for Brain Imaging, University of South Carolina, Columbia, SC 29208, USA. Electronic address:

Published: May 2016

Background: Clinical imaging data are typically stored and transferred in the DICOM format, whereas the NIfTI format has been widely adopted by scientists in the neuroimaging community. Therefore, a vital initial step in processing the data is to convert images from the complicated DICOM format to the much simpler NIfTI format. While there are a number of tools that usually handle DICOM to NIfTI conversion seamlessly, some variations can disrupt this process.

New Method: We provide some insight into the challenges faced with image conversion. First, different manufacturers implement the DICOM format differently which complicates the conversion. Second, different modalities and sub-modalities may need special treatment during conversion. Lastly, the image transferring and archiving can also impact the DICOM conversion.

Results: We present results in several error-prone domains, including the slice order for functional imaging, phase encoding direction for distortion correction, effect of diffusion gradient direction, and effect of gantry correction for some imaging modality.

Comparison With Existing Methods: Conversion tools are often designed for a specific manufacturer or modality. The tools and insight we present here are aimed at different manufacturers or modalities.

Conclusions: The imaging conversion is complicated by the variation of images. An understanding of the conversion basics can be helpful for identifying the source of the error. Here we provide users with simple methods for detecting and correcting problems. This also serves as an overview for developers who wish to either develop their own tools or adapt the open source tools created by the authors.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jneumeth.2016.03.001DOI Listing

Publication Analysis

Top Keywords

dicom format
12
dicom nifti
8
conversion
8
nifti conversion
8
nifti format
8
dicom
6
format
5
tools
5
step neuroimaging
4
neuroimaging data
4

Similar Publications

Mechanical behavior of external root resorption cavities restored with different materials: a 3D-FEA study.

BMC Oral Health

January 2025

Faculty of Dentistry, Department of Endodontics, Ondokuz Mayis University, Samsun, Kurupelit, 55139, Turkey.

Background: The aim was to evaluate the stresses in teeth, with external root resorption (ERR) restored with different materials using finite element analysis (FEA).

Methods: In this study, a Micro-CT scan was conducted on a prepared maxillary central tooth. DICOM-compatible images obtained from the sections were converted into stereolithography format using Ctan software.

View Article and Find Full Text PDF

Purpose: Cochlear implants (CI) are the most successful bioprosthesis in medicine probably due to the tonotopic anatomy of the auditory pathway and of course the brain plasticity. Correct placement of the CI arrays, respecting the inner ear anatomy are therefore important. The ideal trajectory to insert a cochlear implant array is defined by an entrance through the round window membrane and continues as long as possible parallel to the basal turn of the cochlea.

View Article and Find Full Text PDF

Objectives: The current study was conducted to assess the volume of the tongue, oral cavity, and tongue/oral cavity and their correlation with the volume of the upper airway in cleft subjects compared with the control group.

Methods: The study population included 60 CBCT images from dental school. The sample comprised 30 unilateral cleft patients and 30 sex and age-matched healthy subjects.

View Article and Find Full Text PDF

Predictor of diplopia in pure orbital blowout fracture: A 14-year retrospective analysis.

J Stomatol Oral Maxillofac Surg

January 2025

Dept of Oral & Maxillofacial Surgery, Faculty of Dentistry, Universiti Kebangsaan Malaysia, 50300 Kuala Lumpur, Malaysia. Electronic address:

Introduction: Orbital fractures are common among maxillofacial injuries. The primary objective of this study was to investigate the clinical and radiographic characteristics of pure orbital blowout fractures (OBFs) and their association with post-traumatic diplopia. The secondary objective was to identify predictors of diplopia in pure OBFs.

View Article and Find Full Text PDF

Analyzing temporal imaging patterns in acute ischemic stroke via DICOM-timestamps.

Sci Rep

January 2025

Medical Physics, Department of Diagnostic and Interventional Radiology, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, 79106, Freiburg, Germany.

Acute stroke management is time-sensitive, making time data crucial for both research and quality management. However, these time data are often not reliably captured in routine clinical practice. In this proof-of-concept study we analysed image-based time data automatically captured in the DICOM format.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!