Objectives: To evaluate angiographic and clinical results of ZES compared with EES after recanalization of CTOs.
Background: ZES and EES showed similar clinical results in non-CTO lesions. Whether ZES and EES are also comparable in true CTO lesions (TIMI 0 flow, duration of occlusion of more than 3 months) with a higher risk of restenosis has not been addressed so far.
Methods: 125 patients with successful CTO recanalization via antegrade or retrograde approach were included. EES were implanted in 68 patients and ZES in 57 patients. Dual antiplatelet therapy was prescribed for 12 months. Follow-up angiography was scheduled at 9 months and clinical follow-up at 12 months. The primary angiographic outcome measure was in-stent late lumen loss. Primary clinical outcome measures were target lesion revascularization rate (TLR) and major adverse cardiac events (MACE) as a composite of cardiac death, TLR and myocardial infarction not clearly attributable to a non-target vessel.
Results: Baseline characteristics were similar in both groups. Mean stent length was 72.8 ± 33.0mm with EES and 70.8 ± 31.5 mm with ZES (P = 0.72). In-stent late lumen loss was 0.50 ± 0.71 mm for EES compared with 0.59 ± 0.72 (P = 0.52) for ZES. There were similar rates for TLR (EES 10.3% versus ZES 10.5%, P = 0.97) and MACE (EES 10.3% versus ZES 12.3%). No definite or probable stent thrombosis occurred. Stent length but not type of stent was predictive for in-stent late loss and TLR.
Conclusion: ZES and EES showed similar angiographic and clinical outcomes for treatment of CTOs. © 2016 Wiley Periodicals, Inc.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/ccd.26482 | DOI Listing |
Pharmacoecon Open
January 2025
Department of Cardiology, Thoraxcentrum Twente, Medisch Spectrum Twente, Koningsplein 1, 7512 KZ, Enschede, The Netherlands.
Background And Objective: Evidence on health economic outcomes for percutaneous coronary intervention (PCI) comparing different contemporary drug-eluting stents (DES) with each other is scarce, as most previous randomised DES trials did not assess such aspects. This prespecified health economic evaluation of the Comparison of Biodegradable Polymer and Durable Polymer Drug-Eluting Stents in an All Comers Population (BIO-RESORT) trial aimed to compare at 3-year follow-up both health effects and costs of PCI with one of three new-generation drug-eluting stents (DES) in patients with obstructive coronary artery disease.
Methods: The randomised BIO-RESORT trial assessed in 3514 patients the ultrathin-strut biodegradable polymer Orsiro sirolimus-eluting stent (SES) and very-thin-strut Synergy everolimus-eluting (EES) stent versus the thin-strut durable polymer Resolute Integrity zotarolimus-eluting stent (ZES).
Clin Cardiol
June 2024
Department of Cardiology, Detroit Medical Center, Wayne State University, Detroit, Michigan, USA.
Introduction: Long-term follow-up results of various trials comparing Zotarolimus eluting stents (ZES) with Everolimus eluting stents (EES) have been published recently. Additionally, over the last decade, there have been new trials comparing the ZES with various commercially available EES. We aim to conduct an updated meta-analysis in light of new evidence from randomized controlled trials (RCTs) to provide comprehensive evidence regarding the temporal trends in the clinical outcomes.
View Article and Find Full Text PDFCatheter Cardiovasc Interv
July 2024
CVPath Institute, Inc., Gaithersburg, Maryland.
Background: During the transition from dual antiplatelet therapy (DAPT) to single antiplatelet therapy (SAPT), previous studies have raised concerns about a rebound effect. We compared platelet and inflammatory cell adhesion on different types of stents in the setting of clopidogrel presence and withdrawal.
Methods: In Experiment 1, three pigs were administered with DAPT, that is, clopidogrel and acetylsalicylic acid (ASA), for 7 days.
Med Devices (Auckl)
February 2024
Division of Cardiovascular Medicine, Lahey Hospital and Medical Center, Burlington, MA, USA.
Objective: To demonstrate the use of the Data Extraction and Longitudinal Trend Analysis (DELTA) system in the National Evaluation System for health Technology's (NEST) medical device surveillance cloud environment by analyzing coronary stent safety using real world clinical data and comparing results to clinical trial findings.
Design And Setting: Electronic health record (EHR) data from two health systems, the Social Security Death Master File, and device databases were ingested into the NEST cloud, and safety analyses of two stents were performed using DELTA.
Participants And Interventions: This is an observational study of patients receiving zotarolimus drug-eluting coronary stents (ZES) or everolimus eluting coronary stents (EES) between July 1, 2015 and December 31, 2017.
Catheter Cardiovasc Interv
September 2023
Department of Interventional Cardiology, Thoraxcenter, Erasmus University Medical Centre, Rotterdam, The Netherlands.
Objectives: To evaluate the stent expansion of the durable-polymer Zotarolimus-eluting stent (dp-ZES), the durable-polymer Everolimus-eluting stent (dp-EES), and the bioabsorbable-polymer Sirolimus-eluting stent (bp-SES) in calcified coronary chronic total occlusions (CTO).
Background: The newer generation stents with ultrathin struts might raise concerns regarding reduced radial strength and higher stent recoil (SR) when implanted in calcified CTOs.
Methods: Between January 2017 and June 2021 consecutive patients with CTO undergoing percutaneous coronary intervention with dp-ZES, dp-EES, or bp-SES were evaluated.