Do the Threshold Limit Values for Work in Hot Conditions Adequately Protect Workers?

Med Sci Sports Exerc

1Human and Environmental Physiology Research Unit, School of Human Kinetics, University of Ottawa, Ottawa, ON, CANADA; 2FAME Laboratory, Department of Exercise Science, University of Thessaly, Trikala, GREECE; and 3BBE Consulting Canada, Copper Cliff, ON, CANADA.

Published: June 2016

Purpose: We evaluated core temperature responses and the change in body heat content (ΔHb) during work performed according to the ACGIH threshold limit values (TLV) for heat stress, which are designed to ensure a stable core temperature that does not exceed 38.0°C.

Methods: Nine young males performed a 120-min work protocol consisting of cycling at a fixed rate of heat production (360 W). On the basis of the TLV, each protocol consisted of a different work-rest (WR) allocation performed in different wet-bulb globe temperatures (WBGT). The first was 120 min of continuous (CON) cycling at 28.0°C WBGT (CON[28.0°C]). The remaining three protocols were intermittent work bouts (15-min duration) performed at various WR and WBGT: (i) WR of 3:1 at 29.0°C (WR3:1[29.0°C]), (ii) WR of 1:1 at 30.0°C (WR1:1[30.0°C]), and (iii) WR of 1:3 at 31.5°C (WR1:3[31.5°C]) (total exercise time: 90, 60, and 30 min, respectively). The change in rectal (ΔTre) and mean body temperature (ΔTb) was evaluated with thermometry. ΔHb was determined via direct calorimetry and also used to calculate ΔTb.

Results: Although average rectal temperature did not exceed 38.0°C, heat balance was not achieved during exercise in any work protocol (i.e., rate of ΔTre > 0°C·min; all P values ≤ 0.02). Consequently, it was projected that if work was extended to 4 h, the distribution of participant core temperatures higher and lower than 38.0°C would be statistically similar (all P values ≥ 0.10). Furthermore, ΔHb was similar between protocols (P = 0.70). However, a greater ΔTb was observed with calorimetry relative to thermometry in WR3:1[29.0°C] (P = 0.03), WR1:1[30.0°C] (P = 0.02), and WR1:3[31.5°C] (P < 0.01) but not CON[28.0°C] (P = 0.32).

Conclusion: The current study demonstrated that heat balance was not achieved and ΔTb and ΔHb were inconsistent, suggesting that the TLV may not adequately protect workers during work in hot conditions.

Download full-text PDF

Source
http://dx.doi.org/10.1249/MSS.0000000000000886DOI Listing

Publication Analysis

Top Keywords

threshold limit
8
limit values
8
work hot
8
hot conditions
8
adequately protect
8
core temperature
8
temperature exceed
8
work protocol
8
heat balance
8
balance achieved
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!