Fluoroscopic procedures are an area of special concern in relation to radiation protection. The aim of this study was to describe the current level of patient radiation doses in endoscopic retrograde cholangiopancreatography (ERCP) collected from a single centre, as well as to establish and review local diagnostic reference levels (DRLs) in ERCP. A total of 100 patients' radiation doses in ERCP were recorded, and the third-quartile method was adopted to establish local DRLs for ERCP. The mean dose area product (DAP) was 2.05 Gy cm2, fluoroscopy time (FT) 1.7 min and the number of images was 3. The proposed local DRLs for ERCP were 3.00 Gy cm2 and 3.0 min. Local DRLs were reviewed in a sample of 25 patients 5 y after they had been established. In reviewing data, the averages of DAP and FT were below the local DRLs. Local DRLs help in the optimisation process of fluoroscopic procedures and guides to a good clinical practice.

Download full-text PDF

Source
http://dx.doi.org/10.1093/rpd/ncw018DOI Listing

Publication Analysis

Top Keywords

local drls
20
drls ercp
12
local diagnostic
8
diagnostic reference
8
reference levels
8
endoscopic retrograde
8
retrograde cholangiopancreatography
8
fluoroscopic procedures
8
radiation doses
8
local
6

Similar Publications

Chest and abdomen radiographs are the most common radiograph examinations conducted in the Dubai Health sector, with both involving exposure to several radiosensitive organs. Diagnostic reference levels (DRLs) are accepted as an effective safety, optimization, and auditing tool in clinical practice. The present work aims to establish a comprehensive projection and weight-based structured DRL system that allows one to confidently highlight healthcare centers in need of urgent action.

View Article and Find Full Text PDF

Objective: To establish local diagnostic reference levels (DRLs) for pediatric neck CT based on age, weight, and water-equivalent diameter (WED) across multiple university hospitals in South Korea.

Materials And Methods: This retrospective study analyzed pediatric neck CT examinations from nine university hospitals, involving patients aged 0-18 years. Data were categorized by age, weight, and WED, and radiation dose metrics, including volume CT dose index (CTDI) and dose length product, were recorded.

View Article and Find Full Text PDF

Establishment of Local Diagnostic Reference Levels for Head CT Imaging in the Madina Region, Saudi Arabia.

Diagnostics (Basel)

December 2024

Medical Diagnostic Imaging Department, College of Health Science, University of Sharjah, Sharjah 27272, United Arab Emirates.

: Computed Tomography (CT) is crucial in medical diagnosis, particularly for head examinations. Diagnostic Reference Levels (DRLs) are pivotal in balancing diagnostic efficacy with radiation safety. International organizations such as the International Atomic Energy Agency (IAEA) and the International Commission on Radiological Protection (ICRP) provide guidelines for establishing DRLs, emphasizing their importance in optimizing radiation doses.

View Article and Find Full Text PDF

Objective: In suspected acute ischemic stroke, it is now reasonable to expand the conventional "stroke protocol" (non-contrast computed tomography (NCCT), arterial CT angiography (CTA), and optionally CT perfusion (CTP)) to early and late venous head scans yielding a multiphase CTA (MP-CTA) to increase diagnostic confidence. Diagnostic reference levels (DRLs) have been defined for neither MP-CTA nor CTP. We therefore present dosimetry data, while also considering image quality, for a large, unselected patient cohort.

View Article and Find Full Text PDF

Local corner smoothing based on deep learning for CNC machine tools.

Sci Rep

January 2025

College of Intelligent systems Science and Engineering, Harbin Engineering University, Harbin, 150006, China.

Most of toolpaths for machining is composed of series of short linear segments (G01 command), which limits the feedrate and machining quality. To generate a smooth machining path, a new optimization strategy is proposed to optimize the toolpath at the curvature level. First, the three essential components of optimization are introduced, and the local corner smoothness is converted into an optimization problem.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!