Electron cyclotron resonance ion source (ECRIS) plasmas are prone to kinetic instabilities due to anisotropic electron velocity distribution. The instabilities are associated with strong microwave emission and periodic bursts of energetic electrons escaping the magnetic confinement. The instabilities explain the periodic ms-scale oscillation of the extracted beam current observed with several high performance ECRISs and restrict the parameter space available for the optimization of extracted beam currents of highly charged ions. Experiments with the JYFL 14 GHz ECRIS have demonstrated that due to the instabilities the optimum Bmin-field is less than 0.8BECR, which is the value suggested by the semiempirical scaling laws guiding the design of ECRISs.

Download full-text PDF

Source
http://dx.doi.org/10.1063/1.4931716DOI Listing

Publication Analysis

Top Keywords

extracted beam
8
instabilities
5
limitation ecris
4
ecris performance
4
performance kinetic
4
kinetic plasma
4
plasma instabilities
4
instabilities invited
4
invited electron
4
electron cyclotron
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!