We describe an experimental method to measure the gate profile of an x-ray framing camera and to determine several important functional parameters: relative gain (between strips), relative gain droop (within each strip), gate propagation velocity, gate width, and actual inter-strip timing. Several of these parameters cannot be measured accurately by any other technique. This method is then used to document cross talk-induced gain variations and artifacts created by radiation that arrives before the framing camera is actively amplifying x-rays. Electromagnetic cross talk can cause relative gains to vary significantly as inter-strip timing is varied. This imposes a stringent requirement for gain calibration. If radiation arrives before a framing camera is triggered, it can cause an artifact that manifests as a high-intensity, spatially varying background signal. We have developed a device that can be added to the framing camera head to prevent these artifacts.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1063/1.4941754 | DOI Listing |
Front Robot AI
January 2025
Life- and Neurosciences, Frankfurt Institute for Advanced Studies, Frankfurt am Main, Germany.
Biological vision systems simultaneously learn to efficiently encode their visual inputs and to control the movements of their eyes based on the visual input they sample. This autonomous joint learning of visual representations and actions has previously been modeled in the Active Efficient Coding (AEC) framework and implemented using traditional frame-based cameras. However, modern event-based cameras are inspired by the retina and offer advantages in terms of acquisition rate, dynamic range, and power consumption.
View Article and Find Full Text PDFSci Rep
January 2025
The Alan Turing Institute, London, UK.
Air pollution in cities, especially NO, is linked to numerous health problems, ranging from mortality to mental health challenges and attention deficits in children. While cities globally have initiated policies to curtail emissions, real-time monitoring remains challenging due to limited environmental sensors and their inconsistent distribution. This gap hinders the creation of adaptive urban policies that respond to the sequence of events and daily activities affecting pollution in cities.
View Article and Find Full Text PDFIn the realm of 3D measurement, photometric stereo excels in capturing high-frequency details but suffers from accumulated errors that lead to low-frequency distortions in the reconstructed surface. Conversely, light field (LF) reconstruction provides satisfactory low-frequency geometry but sacrifices spatial resolution, impacting high-frequency detail quality. To tackle these challenges, we propose a photometric stereoscopic light field measurement (PSLFM) scheme that harnesses the strengths of both methods.
View Article and Find Full Text PDFJ Opt Soc Am A Opt Image Sci Vis
August 2024
In the pinhole point diffraction interferometer (PPDI), proper alignment between the reflection spot of the tested component and the pinhole is critical to obtain accurate interferograms. At present, adjusting for tilt error requires manual manipulation, and defocus error cannot be corrected. These limitations impede the instrumentation process of PPDI.
View Article and Find Full Text PDFNeurophotonics
January 2025
Northeastern University, Department of Bioengineering, Boston, Massachusetts, United States.
Significance: Functional brain imaging experiments in awake animals require meticulous monitoring of animal behavior to screen for spontaneous behavioral events. Although these events occur naturally, they can alter cell signaling and hemodynamic activity in the brain and confound functional brain imaging measurements.
Aim: We developed a centralized, user-friendly, and stand-alone platform that includes an animal fixation frame, compact peripheral sensors, and a portable data acquisition system.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!