Objective: To evaluate the clinical utility of a novel means of assessing the cervix by measuring the angle of the curvature and to evaluate the performance of this technique as well as two other commonly used techniques of cervical length assessment in predicting spontaneous preterm birth (SPTB).

Methods: This was a retrospective cohort analysis of singleton gestations with a history of SPTB. Transvaginal ultrasound images of cervical length obtained between 20 and 23 6/7 weeks were re-measured using three techniques: (1) straight linear distance between the internal and external os, (2) sum of two contiguous linear segments tracing the internal to the external os, and (3) measurement of the angle of the curve within the cervix using an electronic protractor. A short cervical length was defined as ≤25 mm.

Results: A total of 181 women were included. The relative risk (RR) for SPTB by cervical angle ≤160° was 1.2 (95% CI 0.7-2.0) and the ROC curve revealed an area under the curve of 0.54 (95% CI 0.44-0.63). The RR for SPTB by short cervical length measured by the straight technique was 2.3 (95% CI 1.3-4.0) and by the segmental technique 2.1 (95% CI 1.2-3.8). There was a 99.4% agreement between the two techniques with an intraclass Kappa coefficient of 0.96.

Conclusions: In women with a history of SPTB, cervical angle measurement does not correlate with the risk of SPTB. Cervical length measured via straight and segmental techniques had excellent agreement in identifying short cervix, and both identified a short cervix predictive of SPTB.

Download full-text PDF

Source
http://dx.doi.org/10.3109/14767058.2016.1160049DOI Listing

Publication Analysis

Top Keywords

cervical length
24
sptb cervical
12
spontaneous preterm
8
preterm birth
8
history sptb
8
internal external
8
short cervical
8
risk sptb
8
length measured
8
measured straight
8

Similar Publications

Clinical comparative study of robot-assisted and traditional laparoscopic surgery in patients with cervical cancer: a retrospective cohort study.

BMC Surg

December 2024

Department of Phase I Clinical Research Center, The First Affiliated Hospital of Chongqing Medical University, Chongqing, 400016, China.

Background: A new era in minimally invasive surgery has been ushered in by Leonardo's robot surgical system, but the safety and effectiveness in cervical cancer is lake of evidence. This study aimed to compare the safety, effectiveness, and cost-effectiveness of robot-assisted laparoscopic radical hysterectomy (RRH) and conventional laparoscopic radical hysterectomy (LRH) in patients with cervical cancer.

Methods: Patients with cervical cancer who had radical surgery at the first affiliated Hospital of Chongqing Medical University between January 2017 and June 2022 were enrolled.

View Article and Find Full Text PDF

The quantity of cable conductors is a crucial parameter in cable manufacturing, and accurately detecting the number of conductors can effectively promote the digital transformation of the cable manufacturing industry. Challenges such as high density, adhesion, and knife mark interference in cable conductor images make intelligent detection of conductor quantity particularly difficult. To address these challenges, this study proposes the YOLO-cable model, which is an improvement made upon the YOLOv10 model.

View Article and Find Full Text PDF

Past research has demonstrated the association between social engagement and the maintenance of cognitive abilities. However, inconsistent definitions of social engagement have posed challenges to systematically investigate this association. This paper addresses the role of social relationships in cognitive functioning among older adults, focusing on the real-life communication indicator-length of own speech-as a measure of social activity.

View Article and Find Full Text PDF

Objectives: This study aimed to evaluate the predictive abilities of the 5-item modified Frailty Index (5-mFI), Prognostic Nutrition Index (PNI), and their combination in older adult patients undergoing oral cancer resection and free flap reconstruction.

Design: Retrospective cohort study.

Setting: Secondary care involving multiple centres treating older adult patients for oral cancer.

View Article and Find Full Text PDF

Objective: To explore the anatomic characteristics of C7 nerve localization, course, and length during cross-transfer surgery of the C7 nerve through the anterior vertebral approach and investigate the feasibility, safety, and clinical efficacy of C7 nerve transfer surgery through the anterior vertebral approach for the treatment of central upper limb spastic paralysis.

Methods: Four fresh-frozen adult head and neck samples were selected. C7 nerve transfer surgery was simulated through the anterior vertebral approach.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!