Applicability of refractometry for fast routine checking of hospital preparations.

Eur J Pharm Sci

KU Leuven - University of Leuven, Department of Pharmaceutical and Pharmacological Sciences, Pharmaceutical Analysis, B-3000 Leuven, Belgium. Electronic address:

Published: April 2016

Quality control of hospital pharmacy formulations is of the utmost importance to ensure constant quality and to avoid potential mistakes before administration to the patient. In this study we investigated the applicability of refractometry as a fast, inexpensive and easy-to-use quality control measurement. Refractive indices (RI) of a multitude of different hospital formulations with varying concentrations of active compound were measured. The samples consisted of a number of binary aqueous solutions (one compound in water), complex aqueous solutions (multiple compounds in water or in a constant matrix), two suspensions and one emulsion. For all these formulations, linear regression analysis was performed, quality control limits determined and accuracy and repeatability were checked. Subsequently, actual hospital pharmacy samples were analyzed to check whether they were within the specified limits. For both binary and complex aqueous formulations, repeatability was good and a linear correlation for all samples could be observed on condition that the concentration of the active compound was sufficiently high. The refractometer was not sensitive enough for solutions of folic acid and levothyroxine, which had too low a concentration of active compound. Due to lack of homogeneity and light scattering, emulsions and suspensions do not seem suitable for quality control by refractometry. A mathematical equation was generated to predict the refractive index of an aqueous solution containing clonidine HCl as active compound. Values calculated from the equation were compared with measured values and deviations of all samples were found to be lower than 1.3%. In order to use refractometry in a hospital pharmacy for quality control of multicomponent samples, additional intermediate measurements would be required, to overcome the fact that refractometry is not compound specific. In conclusion, we found that refractometry could potentially be useful for daily, fast quality measurements of relatively concentrated binary and more complex aqueous solutions in the hospital pharmacy.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ejps.2016.02.014DOI Listing

Publication Analysis

Top Keywords

quality control
20
hospital pharmacy
16
active compound
16
aqueous solutions
12
complex aqueous
12
applicability refractometry
8
refractometry fast
8
binary complex
8
concentration active
8
quality
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!