A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A novel computed method to reconstruct the bilateral digital interarticular channel of atlas and its use on the anterior upper cervical screw fixation. | LitMetric

Purpose. To investigate a novel computed method to reconstruct the bilateral digital interarticular channel of atlas and its potential use on the anterior upper cervical screw fixation. Methods. We have used the reverse engineering software (image-processing software and computer-aided design software) to create the approximate and optimal digital interarticular channel of atlas for 60 participants. Angles of channels, diameters of inscribed circles, long and short axes of ellipses were measured and recorded, and gender-specific analysis was also performed. Results. The channels provided sufficient space for one or two screws, and the parameters of channels are described. While the channels of females were smaller than that of males, no significant difference of angles between males and females were observed. Conclusion. Our study demonstrates the radiological features of approximate digital interarticular channels, optimal digital interarticular channels of atlas, and provides the reference trajectory of anterior transarticular screws and anterior occiput-to-axis screws. Additionally, we provide a protocol that can help make a pre-operative plan for accurate placement of anterior transarticular screws and anterior occiput-to-axis screws.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4768695PMC
http://dx.doi.org/10.7717/peerj.1737DOI Listing

Publication Analysis

Top Keywords

digital interarticular
20
interarticular channel
12
channel atlas
12
novel computed
8
computed method
8
method reconstruct
8
reconstruct bilateral
8
bilateral digital
8
anterior upper
8
upper cervical
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!