DrugCam(®) is a new approach to control the chemotherapy preparations with an intelligent video system that enables automatic verification during the critical stages of preparations combined with an a posteriori control with partial or total visualization of the video recording of preparations. The assessment was about the recognizing of anticancer drug vials (qualitative analysis) and syringe volumes (quantitative analysis). The qualitative analysis was conducted for a total of 120 vials with sensitivity of 100% for 84.2% of the vials and at least 97% for all the vials tested. Accuracy was at least 98.5% for all vials. The quantitative analysis was assessed by detecting 10 measures of each graduation for syringes. The identification error rate was 2.1% (244/11,640) i.e. almost 94% to the next graduation. Only 3% (35/1164) of the graduations tested, i.e. 23/35 for volume <0.13 ml of 1 ml syringes, presented a volume error outside the admissible limit of ± 5% of a confidence band constructed for the estimated linear regression line for each syringe. In addition to the vial detection model, barcodes can also read when they are present on vials. DrugCam(®) offers an innovative approach for controlling chemotherapy preparations and constitutes an optimized application of telepharmacy.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ijpharm.2016.02.028DOI Listing

Publication Analysis

Top Keywords

intelligent video
8
qualitative analysis
8
quantitative analysis
8
vials
5
drugcam®-an intelligent
4
video camera
4
camera system
4
system safe
4
safe cytotoxic
4
cytotoxic drug
4

Similar Publications

Widespread screening is crucial for the early diagnosis and treatment of glaucoma, the leading cause of visual impairment and blindness. The development of portable technologies, such as smartphone-based ophthalmoscopes, able to image the optical nerve head, represents a resource for large-scale glaucoma screening. Indeed, they consist of an optical device attached to a common smartphone, making the overall device cheap and easy to use.

View Article and Find Full Text PDF

Gibbons, a type of lesser ape, are brachiators but also walk bipedally and without forelimb assistance, not only on the ground but also on tree branches. The arboreal bipedal walking strategy of the gibbons has been studied in previous studies in relation to two-dimensional (2D) kinematic analysis. However, because tree branches and the ground differ greatly in width, leading to a constrained foot contact point on the tree branches, gibbons must adjust their 3D joint motions of trunk and hindlimb on the tree branches.

View Article and Find Full Text PDF

Objectives: This study aimed to develop an automated skills assessment tool for surgical trainees using deep learning.

Background: Optimal surgical performance in robot-assisted surgery (RAS) is essential for ensuring good surgical outcomes. This requires effective training of new surgeons, which currently relies on supervision and skill assessment by experienced surgeons.

View Article and Find Full Text PDF

Quantitative investigation of a 3D bubble trapper in a high shear stress microfluidic chip using computational fluid dynamics and L*A*B* color space.

Biomed Microdevices

January 2025

Chakri Naruebodindra Medical Institute, Faculty of Medicine Ramathibodi Hospital, Mahidol University, 111 Suwannabhumi Canal Rd, Bang Pla, Bang Phli District, Samut Prakan, 10540, Thailand.

Microfluidic chips often face challenges related to the formation and accumulation of air bubbles, which can hinder their performance. This study investigated a bubble trapping mechanism integrated into microfluidic chip to address this issue. Microfluidic chip design includes a high shear stress section of fluid flow that can generate up to 2.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!