Prospective Comparative Analysis of 4 Different Intraocular Pressure Measurement Techniques and Their Effects on Pressure Readings.

J Glaucoma

*University of Toronto School of Medicine †Department of Ophthalmology and Vision Sciences, University of Toronto, Toronto, ON, Canada.

Published: October 2016

Purpose: To compare intraocular pressure (IOP) measurement using the Goldmann applanation tonometry (GAT) without fluorescein, with fluorescein strips, with fluorescein droplets, and IOP measurement with Tono-Pen Avia (TPA).

Patients And Methods: This was a prospective comparative clinical analysis. It was performed in clinical practice. The study population consisted of 40 volunteer patients, 1 eye per patient. All patients who were 18 years and older having routine ophthalmological examination were eligible to participate. Active corneal abrasions and/or ulcers, previous glaucoma surgery, or prostheses interfering with GAT measurement were excluded. GAT IOP was measured first without fluorescein, then with fluorescein strip, then with fluorescein droplet, and finally with the TPA device. The main outcome measure was central corneal IOP.

Results: Mean±SD IOP measurements for GAT without fluorescein, with fluorescein strip, with fluorescein droplet, and for TPA groups were 12.65±3.01, 14.70±2.82, 15.78±2.64, and 16.33±3.08 mm Hg, respectively. Repeated-measures analysis of variance corrected with the Greenhouse-Geisser estimate ([Latin Small Letter Open E]=0.732) showed that measuring technique had a significant effect on IOP measurements (F2.20,85.59=34.66, P<0.001). The pairwise post hoc testing showed statistically significant mean differences (P≤0.001) between all techniques except when GAT with fluorescein droplet was compared with TPA (P=0.222). The Bland-Altman analyses showed 95% limits of agreement maximum potential discrepancies in measurement ranging from 5.89 mm Hg in the GAT with fluorescein strip versus droplet compared with 11.83 mm Hg in the GAT with fluorescein strip versus TPA comparison.

Conclusions: IOP measurement technique significantly impacted the values obtained. The ophthalmologist should ensure consistent measurement technique to minimize variability when following patients.

Download full-text PDF

Source
http://dx.doi.org/10.1097/IJG.0000000000000403DOI Listing

Publication Analysis

Top Keywords

fluorescein fluorescein
12
fluorescein
9
prospective comparative
8
intraocular pressure
8
iop measurement
8
gat fluorescein
8
fluorescein strip
8
strip fluorescein
8
fluorescein droplet
8
iop measurements
8

Similar Publications

Background And Aims: Probe-based confocal endomicroscopy (pCLE) allows real-time microscopic visualization of the intestinal mucosa surface layers. Despite remission achieved through anti-tumor necrosis factor or vedolizumab therapy, anomalies in the intestinal epithelial barrier are observed in inflammatory bowel disease (IBD) patients. Our study aimed to assess these abnormalities in non-IBD individuals and compare them with IBD patients in endoscopic remission to identify the associated factors.

View Article and Find Full Text PDF

Retinal Vasculitis as a Rare Presentation of Microscopic Polyangiitis.

Cureus

December 2024

Internal Medicine, Unidade Local de Saúde de Coimbra, Coimbra, PRT.

Microscopic polyangiitis (MPA) is a rare, autoimmune, small-vessel vasculitis usually described with the presence of perinuclear antineutrophil cytoplasmic antibodies (p-ANCA). It encompasses a broad spectrum of clinical features, including fatigue, weight loss, fever, arthralgia, skin lesions, and involvement of the lungs or kidneys. Ocular manifestations, however, are extremely rare.

View Article and Find Full Text PDF

Exposure of lung epithelia to aerosols is omnipresent. Chronic exposure to polluted air is a significant factor in the development of pulmonary diseases, which are among the top global causes of death, including COVID-19, chronic obstructive pulmonary disease, lung cancer, and tuberculosis. As efforts to prevent and treat lung diseases increase, the development of pulmonary drug delivery systems has become a major area of interest.

View Article and Find Full Text PDF

Purpose: We report a case of Eales disease in Inuit and reflect on advances in telemedicine and treatment of retinal disease since the first report of Eales' disease in Greenlandic Inuit was published.

Patients And Methods: A 41-year-old Inuit female complaining of blurred vision was referred to our eye department. There had been no sign of diabetic retinopathy during diabetic eye screening and the patient had been treated for tuberculosis in 2010.

View Article and Find Full Text PDF

Background: To compare structural and vascular parameters between advanced pseudoexfoliation glaucoma (PXG) and primary open-angle glaucoma (POAG).

Methods: One hundred and six eyes of 81 patients were enrolled in this cross-sectional study. All patients underwent complete ophthalmic examination and measurement of the thickness of the peripapillary retinal nerve fiber layer (RNFL) and ganglion cell complex (GCC).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!