A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

In Vitro Assessment of Three Clinical Lithotripters Employing Different Shock Wave Generators. | LitMetric

Objective: To test the hypothesis that shock wave lithotripsy machines vary in their ability to fragment standardized artificial urinary calculi.

Materials And Methods: An in vitro test configuration was used to fragment synthetic U-30 Gypsum (U.S. Gypsum, Chicago, IL) stones (mean length 7.1 ± 0.2 mm, mean diameter 6.5 ± 0.07 mm, mean mass 299 ± 16 mg) using the Sonolith i-sys (EDAP TMS, Vaulx-en-Velin, France), Modulith SLX F2 (Storz Medical AG, Tägerwilen, Switzerland), and Piezolith 3000 (Richard Wolf GmbH, Knittlingen, Germany) lithotripters. Gypsum stones were placed at the nominal focus and treated with 250, 500, or 1000 shocks. The residual mass following passage through a 2-mm wire mesh was measured and compared using ANOVA and the Tukey-Kramer HSD test.

Results: There was no statistically significant difference between the Modulith SLX F2 and Piezolith 3000 lithotripters for 250 and 1000 shock treatments (p = 0.34 and 0.31, respectively). The Piezolith 3000 demonstrated the most favorable stone mass reduction for 500 shock treatments (187.4 ± 45.2 mg). The Sonolith i-sys was found to be significantly less effective than the other lithotripters for all shockwave conditions. Furthermore, performance of the Sonolith i-sys decreased beyond a threshold generator electrode age of 6000 shocks.

Conclusions: This in vitro study found considerable variability in the ability of lithotripters to fragment synthetic urinary calculi. Synthetic stones were employed to provide a repeatable means of assessing variability in fragmentation efficiency of lithotripters. The Modulith SLX F2 and Piezolith 3000 are broadly equal and resulted in greater fragmentation efficiencies than the Sonolith i-sys. The performance of the Sonolith i-sys deteriorates at 6000 shocks, before the specified lifetime of 20,000 shocks.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4876495PMC
http://dx.doi.org/10.1089/end.2015.0662DOI Listing

Publication Analysis

Top Keywords

sonolith i-sys
20
piezolith 3000
16
modulith slx
12
shock wave
8
fragment synthetic
8
slx piezolith
8
shock treatments
8
performance sonolith
8
lithotripters
6
sonolith
5