Introduction: The reported incidence of incisional hernia following orthotopic liver transplantation (OLT) varies from 4% to 23%. Postoperative wound complications are less frequent after laparoscopic repair while maintaining low recurrence rates. We present our experience in managing this complication.

Materials And Methods: Retrospectively, collected data of all patients who underwent liver transplant and developed incisional hernias were analyzed. Patients' demographic data, anthropometric data, transplantation-related data, and repair-related operative and postoperative data were collected. Risk factors for post-transplant incisional hernia were appraised in our patients. Patients were divided into two groups: Group A included patients who had their incisional hernia repaired through the laparoscopic approach, and Group B included patients who had their incisional hernia repaired through open conventional approach.

Results: A total of 488 liver transplantations were performed at our institution between May 2001 and end of December 2012. Thirty-three patients developed incisional hernias after primary direct closure of the abdominal wall with an overall incidence of 6.9%. Hernia repair was done in 25 patients. Follow-up ranged from 6.4 to 106.1 months with a mean of 48.3 ± 28.3 months. All patients were living at the end of the follow up except four patients (16%). Group A included 13 patients, and Group B included 12 patients. The size of defects and operative time did not differ significantly between both the groups. On the other hand, hospital stay was significantly shorter in laparoscopic group. Complication rate following laparoscopic repair was insignificantly different for open repair.

Conclusion: In experienced hands, laparoscopic incisional hernia repair in post-liver transplant setting proved to be a safe and feasible alternative to open approach and showed superior outcome expressed in shorter hospital stay, with low recurrence and complication rate.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4746977PMC
http://dx.doi.org/10.4103/0972-9941.152102DOI Listing

Publication Analysis

Top Keywords

incisional hernia
24
group included
16
included patients
16
hernia repair
12
patients
11
incisional
8
liver transplantation
8
laparoscopic repair
8
low recurrence
8
developed incisional
8

Similar Publications

Self-gripping versus polypropylene mesh for incisional hernia repair in a rat model.

Surg Endosc

January 2025

Department of Hernia and Abdominal Wall Surgery, The First Affiliated Hospital of Zhengzhou University, No.1 Jianshe Road, Zhengzhou, 450052, Henan, China.

Background: Self-gripping mesh, made of monofilament polypropylene and covered by a layer of polylactic acid micro-hooks, is applied in ventral hernia repair, whereas cytological change and collagen expression around the mesh are rarely reported. The objective of this research was to compare inflammatory response and collagen proliferation between self-gripping and polypropylene mesh in rat model of incisional hernia.

Methods: Forty-five rats were randomly divided into unrepaired (UR) group, polypropylene (PP) mesh group, and self-gripping (SG) mesh group and euthanized at 1, 2 and 4 weeks postoperatively.

View Article and Find Full Text PDF

Laparoscopic repair of Bochdalek hernia with intrathoracic kidney and concomitant redo-redo incisional hernia.

BMJ Case Rep

January 2025

Faculty of Medicine, Department of Surgery, King Chulalongkorn Memorial Hospital, The Thai Red Cross Society, Chulalongkorn University, Bangkok, Thailand.

Bochdalek hernias (BHs), though rare, are the most common congenital diaphragmatic hernias. Their coexistence with an ectopic intrathoracic kidney (IK), found in 0.25% of cases, is even rarer.

View Article and Find Full Text PDF

Background: The role of robot-assisted approach in hernia surgery remains controversial due to high procedural costs and the proposed equal outcomes compared with open surgery. In this study, we report the 30-day results of the introduction of robot-assisted approach in a specialized regional ventral hernia repair center.

Methods: This was a retrospective single-center cohort study including patients undergoing either robot-assisted or open ventral hernia repair from 2017 to 2022.

View Article and Find Full Text PDF

Purpose: Preoperative decision making prior to incisional hernia repair brings benefits but also presents challenges. Defect width (DW) is the key index in hernia staging but does not precisely indicate the requirement for component separation (CS). DW as a percentage of transverse abdominal diameter (TAD) determined by CT imaging was investigated for its capacity to indicate the necessity of CS for successful defect closure under physiological tension.

View Article and Find Full Text PDF

Incisional hernia is a type of iatrogenic disease, and its clinical treatment is complicated. In recent years, there have been new advances in the diagnosis, surgical methods, and materials science of incisional hernias. On the basis of the , more than 70 experts and scholars over the country have discussed the consultation and modified the issues such as complex abdominal wall conditions, loss of domain, principles of incisional hernia treatment, techniques of abdominal wall hernia defects closure, perioperative management, and follow-up in this new edition, combined with evidence-based medical evaluation standards.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!