Introduction: At the time of generator replacement, after ICD implantation for primary prevention, many patients may no longer meet implantation criteria. We investigated the occurrence of ICD therapy after generator replacement in patients initially implanted ICD for primary prevention.

Methods: Patients from 3 hospitals undergoing ICD generator replacement, who were initially implanted for primary prevention, were retrospectively evaluated for occurrence of appropriate ICD therapy after generator replacement. Patients were categorized as to whether or not they had appropriate ICD therapy during their first battery life, and by their left ventricular ejection fraction (LVEF) before generator replacement.

Results: Data from 168 patients were analyzed, with average follow-up after generator replacement of 41.2 ± 26.5 months. Seventy-six (45.2%) patients had ventricular arrhythmia episodes (>180 beats per minutes) and 63 (37.5%) received appropriate ICD therapy during the first battery life. Among 105 patients without ICD therapy before generator replacement, those with an LVEF ≤35% before ICD replacement had higher occurrence of ICD therapy after generator replacement than patients with an LVEF ≥36%. Patients who no longer met primary prevention ICD indications (no ICD therapy and LVEF ≥36% before generator replacement) showed a lower risk for ICD therapy after generator replacement (11.6% over 5-year follow-up).

Conclusions: In patients without ICD therapy before generator replacement, low LVEF (≤35%) contributed to future ICD therapy. In patients initially undergoing ICD implantation for primary prevention, history of ICD therapy during the first battery life and LVEF should be utilized for risk stratification at the time of generator replacement.

Download full-text PDF

Source
http://dx.doi.org/10.1111/jce.12961DOI Listing

Publication Analysis

Top Keywords

generator replacement
48
icd therapy
44
therapy generator
24
primary prevention
20
icd
17
replacement patients
16
generator
13
replacement
13
patients
12
patients longer
12

Similar Publications

Background: Noninferiority of omitting intraoperative defibrillation threshold (DFT) testing has been documented for transvenous implantable cardioverter defibrillators (ICD) whereas data for the subcutaneous-ICD (S-ICD) regarding the need for DFT testing, especially during S-ICD generator replacement, is not available.

Methods: A total of 112 consecutive patients who underwent S-ICD generator replacement and routine testing were included in this retrospective single-center study and analyzed regarding the outcome of intraoperative DFT.

Results: The majority of patients (87.

View Article and Find Full Text PDF

Objective: To maximize local tumor control, stabilize affected bones, and preserve or replace joints with minimal interventional burden, thereby enhancing quality of life for empowered living.

Indications: Suitable for patients with bone metastases, particularly those with severe pain and/or fractures and appropriate life expectancy.

Contraindications: In primary bone tumors, refer to the sarcoma surgery team for evaluation of wide resection.

View Article and Find Full Text PDF

Injection molded parts are increasingly utilized across various industries due to their cost-effectiveness, lightweight nature, and durability. However, traditional defect detection methods for these parts often rely on manual visual inspection, which is inefficient, expensive, and prone to errors. To enhance the accuracy of defect detection in injection molded parts, a new method called MRB-YOLO, based on the YOLOv8 model, has been proposed.

View Article and Find Full Text PDF

Intelligent identification and warning method of disc cutter abnormal wear in TBM construction based on extreme learning machine.

Sci Rep

December 2024

Xinjiang Irtysh River Investment and Development (Group) Co., Ltd., Wulumuqi, 830000, China.

Abnormal cutter wear has a serious impact on TBM construction. If not found in time, it may lead to the cutterhead overall failure. Aiming at this problem, a general model and method to identify and warn the abnormal cutter wear using Extreme Learning Machine (ELM) is proposed.

View Article and Find Full Text PDF

Diagnosis, treatment, and prevention of ankle sprains: Comparing free chatbot recommendations with clinical guidelines.

Foot Ankle Surg

December 2024

Department of Trauma Surgery, Orthopaedics and Plastic Surgery, University of Göttingen, Robert-Koch-Str. 40, Göttingen 37075, Germany. Electronic address:

Background: Free chatbots powered by large language models offer lateral ankle sprains (LAS) treatment recommendations but lack scientific validation.

Methods: The chatbots-Claude, Perplexity, and ChatGPT-were evaluated by comparing their responses to a questionnaire and their treatment algorithms against current clinical guidelines. Responses were graded on accuracy, conclusiveness, supplementary information, and incompleteness, and evaluated individually and collectively, with a 60 % pass threshold.

View Article and Find Full Text PDF