Background: In recent years, increasingly sophisticated tools have allowed for more complex robotic surgery. Robotic hepatectomy, however, is still in its infancy. Our goals were to examine the adoption of robotic hepatectomy and to compare outcomes between open and robotic liver resections.
Methods: The robotic hepatectomy experience of 64 patients was compared to a modern case-matched series of 64 open hepatectomy patients at the same center. Matching was according to benign/malignant diagnosis and number of segments resected. Patient data were obtained retrospectively. The main outcomes and measures were operative time, estimated blood loss, conversion rate (robotic to open), Pringle maneuver use, single non-anatomic wedge resection rate, resection margin size, complication rates (infectious, hepatic, pulmonary, cardiac), hospital stay length, ICU stay length, readmission rate, and 90-day mortality rate.
Results: Sixty-four robotic hepatectomies were performed in 2010-2014. Forty-one percent were segmental and 34 % were wedge resections. There was a 6 % conversion rate, a 3 % 90-day mortality rate, and an 11 % morbidity rate. Compared to 64 matched patients who underwent open hepatectomy (2004-2012), there was a shorter median OR time (p = 0.02), lower median estimated blood loss (p < 0.001), and shorter median hospital stay (p < 0.001). Eleven of the robotic cases were isolated resections of tumors in segments 2, 7, and 8.
Conclusions: Robotic hepatectomy is safe and effective. Increasing experience in more centers will allow definition of which hepatectomies can be performed robotically, and will enable optimization of outcomes and prospective examination of the economic cost of each approach.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4870111 | PMC |
http://dx.doi.org/10.1007/s00268-016-3446-9 | DOI Listing |
Surg Endosc
January 2025
Division of Transplant Surgery, Department of Surgery, Hume- Lee Transplant Center, Virginia Commonwealth University School of Medicine, Richmond, VA, USA.
Background: Robotic living donor hepatectomy offers potential advantages but has been limited to high-volume centers, primarily in Asia and the Middle East. We report our experience establishing a robotic living donor right hepatectomy program in a U.S.
View Article and Find Full Text PDFInt J Surg
January 2025
Division of Hepatobiliary and Transplantation Surgery, Department of General Surgery, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing, China.
Introduction: Laennec's capsule serves as a critical anatomical landmark in anatomical liver resection. Despite its potential, a lack of large-scale prospective studies limits the widespread use of the Laennec approach for minimally invasive hepatectomy. This multicenter cohort study aimed to compare the outcomes of the traditional and Laennec approaches in minimally invasive anatomical hepatectomy across multiple centers in China.
View Article and Find Full Text PDFJ Clin Med
December 2024
Department of Surgery, Fujita Health University Okazaki Medical Center, 1 Gotanda, Harisaki-cho, Okazaki 444-0827, Aichi, Japan.
In Japan, the hinotori™ surgical robot system (Medicaroid Corporation, Kobe, Japan) was approved for gastrointestinal surgeries in October 2022. This report details our initial experience performing liver resection using the hinotori™ system. Ten patients, who were assessed as cases that would benefit from the robot-assisted procedure, underwent liver resections using the hinotori™ system at Fujita Health University, Okazaki Medical Center, between August 2023 and October 2024.
View Article and Find Full Text PDFSurg Endosc
January 2025
Department of Surgery, Weill Cornell Medicine, New York, NY, USA.
Background: Minimally invasive liver surgery (MILS) is superior to open surgery when considering decreased blood loss, fewer complications, shorter hospital stay, and similar or improved oncologic outcomes. However, operative limitations in laparoscopic hepatectomy have curved its applicability and momentum of complex minimally invasive liver surgery. Transitioning to robotic hepatectomy may bridge this complexity gap.
View Article and Find Full Text PDFAnn Surg Oncol
January 2025
Center for Liver and Pancreatobiliary Cancer, National Cancer Center, Goyang-si, Korea.
Background: Anatomical liver resection has been altered by a deeper understanding of the internal structure of the liver, highlighting the importance of the intersegmental plane, a region lacking Glissonean branches. These insights have enabled a novel surgical technique focused on the precise detachment of the intersegmental plane, supported by indocyanine green (ICG) fluorescent imaging and robotic platforms, enhancing the precision and safety of liver resection.
Methods: This study involved four patients who underwent robotic left hepatectomy using the Da Vinci Xi system.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!