Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Pacing-modes selection in sinus-node-dysfunction (SND) patients continues to be a subject of debate. Atrial fibrillation (AF) and cardiac dysfunction remain significant problems following cardiac-pacing therapy. Prevention of these complications is of clinical relevance.
Methods: We performed a collaborative pooled-analysis of randomized trials (RCT) to evaluate the effect of currently available pacing strategies on the risk of post-implantation AF and heart failure events (HF) in SND patients. The primary endpoint was a composite AF and HF events.
Results: Ten RCTs (n = 6639, male 57 %, median follow-up 2.5 years) were included. The pooled-analysis was stratified into two subsets [single chamber atrial pacing (AAI) vs. dual chamber pacing (DDD), and minimal ventricular pacing (MinVP) vs. DDD]. No significant difference was observed in the AAI vs. DDD subset regarding the primary outcome (P = 0.83). Notably, the mean percentage of ventricular-pacing in the MinVP group was 6.5 vs. 77.4 % in the DDD group (P < 0.05), and MinVP was associated with a substantially reduced risk of composite AF and HF (OR 0.66, P = 0.007) in patients receiving pacemaker as primary treatment. However, in the long-term paced patients scheduled for device replacement, there was no significant difference in the rate of primary endpoint between MinVP vs. DDD groups (P > 0.05).
Conclusions: These results support MinVP over conventional DDD for SND patients who received pacemaker as primary treatment in improving the clinical outcome. For patients who already had chronic ventricular-pacing and impaired cardiac function, a device update to MinVP algorithm may exert no favorable effect on the cardiac performance.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00392-016-0973-1 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!