Introduction: The management of chronic mesh infection is challenging and controversial. The use of synthetic material to repair the abdominal wall in the infected setting is not recommended, especially in the presence of active infection caused by Staphylococcus aureus.

Methods: This is a prospective observational study designed to evaluate the outcomes in patients with active mesh infection caused by Staphylococcus aureus. Patients underwent simultaneous removal and replacement of polypropylene mesh. The treatment protocol included the complete removal of infected mesh, followed by the anatomical reconstruction, and reinforcement of the abdominal wall using a new onlay polypropylene mesh. Early and late wound complications, medical complications, and hernia recurrences were analyzed.

Results: From 2006 until 2014, 22 patients with a mean age of 57.2 years and mean BMI of 29,3 kg/m2 were studied. Sinuses were present in 21 patients. A recurrent ventral hernia was observed in 14 patients; two patients required a complex abdominal wall reconstruction due to enteric fistulas. Bowel resections or other potentially contaminated procedures were associated in 10 patients. Fourteen patients (63.6%) had an uneventful postoperative course; 5 (22.7%) patients had wound infections requiring debridement and three required partial (2) or total (1) mesh removal. Two patients died due to medical complications. Adverse results on long-term follow-up included one hernia recurrence after complete mesh removal and one persistent sinus after partial mesh removal requiring a reoperation to remove mesh remnants. All of the patients were considered free of infection after a mean follow-up of 44 months.

Conclusions: Synthetic mesh replacement in patients with active Staphylococcus aureus infection has an acceptable incidence of postoperative wound infection and prevents hernia recurrence. Large-pore polypropylene mesh is a suitable material to be used in the infected surgical field as an onlay graft.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ijsu.2016.02.062DOI Listing

Publication Analysis

Top Keywords

staphylococcus aureus
16
mesh
13
patients
13
mesh infection
12
infection caused
12
caused staphylococcus
12
abdominal wall
12
polypropylene mesh
12
mesh removal
12
active staphylococcus
8

Similar Publications

Introduction: Meticillin resistant (MRSA) is a major contributor to surgical site infections in post-operative patients. Hospital environments harbor MRSA, contributing to higher risk of nosocomial infections. Meticillin resistance is conferred by acquisition of gene, typically carried on mobile genetic element called Staphylococcal Cassette Chromosome (SCC).

View Article and Find Full Text PDF

A colloidal gold immunochromatographic assay (ICA) based on a dual-antibody sandwich method was developed for the rapid and convenient detection of () antigens in the early stages of infection. Monoclonal antibodies designed as 5B3 targeting the conserved region of 56 kDa outer membrane protein in various strains of were generated through cell fusion and screening techniques and combined with previously prepared polyclonal antibodies as detection antibodies to establish the ICA. Colloidal gold and polyclonal antibody-colloidal gold complexes were synthesized under optimized conditions.

View Article and Find Full Text PDF

Ankle fractures, often accompanied by other injuries and complications, pose a significant healthcare burden due to their high incidence and associated treatment challenges. This case report investigates the use of Cytal™ Wound Matrix, derived from urinary bladder matrix (UBM), in managing postoperative complications following open reduction and internal fixation (ORIF) of a trimalleolar ankle fracture. A 57-year-old male with a history of hypertension sustained a trimalleolar ankle fracture following a road traffic accident.

View Article and Find Full Text PDF

This study investigated endophytic fungi isolated from the medicinal plant Panax notoginseng. Among these, the endophytic fungus SQ3, identified as Chaetomium globosum, was capable of reducing silver ions to form metallic silver nanoparticles. The green-synthesized silver nanoparticles (AgNPs) presented a distinct surface plasmon resonance peak at 424 nm, with particle sizes between 2.

View Article and Find Full Text PDF

Anti-inflammatory coupled anti-angiogenic airway stent effectively suppresses tracheal in-stents restenosis.

J Nanobiotechnology

January 2025

Department of Interventional Radiology, Key Laboratory of Interventional Radiology of Henan Province, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, 450001, China.

Excessive vascularization during tracheal in-stent restenosis (TISR) is a significant but frequently overlooked issue. We developed an anti-inflammatory coupled anti-angiogenic airway stent (PAGL) incorporating anlotinib hydrochloride and silver nanoparticles using advanced electrospinning technology. PAGL exhibited hydrophobic surface properties, exceptional mechanical strength, and appropriate drug-release kinetics.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!