This study was conducted on the Fukushima Medical University (FMU) premises (in Fukushima City, Fukushima Prefecture) about four years after the Fukushima Daiichi Nuclear Power Plant accident. Its objectives were (1) to create a map of the ambient gamma dose rate (air-kerma rate) distribution, (2) to evaluate the air-kerma rate originating from natural radionuclides, and (3) to investigate the effects of snow cover on changes in the air-kerma rate. This man-borne survey revealed that the air-kerma rate varies widely, ranging from 0.038 μGy h(-1) to 0.520 μGy h(-1), and is higher on grass than on the other investigated surface types, such as soil, asphalt, and bricks. In this area, the mean air-kerma rate from natural radiation was evaluated to be 0.03 ± 0.01 μGy h(-1), which is close to 0.04 μGy h(-1), which was measured in central Fukushima City by a local authority.Furthermore, snowfall was found to reduce the air-kerma rate by 5%-30%. This reduction was attributed to attenuation of the primary radiation while passing through the snow cover, and the measured contribution of scattered radiation to the air-kerma rate reduction was small. The reduction rate was found to depend on the initial snow depth but to maintain a similar value for a couple of days, after the snow had partially melted and its depth had decreased. Finally, analysis of the daily dose due to external exposure received on the FMU premises revealed that no further health effects due to chronic radiation exposure at this site are to be expected.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5131576PMC
http://dx.doi.org/10.5387/fms.2015-16DOI Listing

Publication Analysis

Top Keywords

air-kerma rate
24
μgy h-1
16
fukushima medical
8
medical university
8
years fukushima
8
fmu premises
8
fukushima city
8
rate
8
snow cover
8
fukushima
7

Similar Publications

Background: Several methods can be used to intraoperatively identify pulmonary lesion using radiation technology. However, little is known about patient radiation exposure during chest surgery. We aimed to measure patients' radiation exposure from cone-beam computed tomography (CBCT) used in a hybrid operating room.

View Article and Find Full Text PDF

Background: Contrast-induced acute kidney injury (CI-AKI) is one of the complications of percutaneous coronary intervention (PCI) with high financial burden and poor outcomes. Dynamic coronary roadmap (DCR) is one of the augmentation tools that can provide a dynamic clear coronary mapping with the potential to reduce contrast use and CI-AKI incidence. Herein, we aim to systematically investigate the studies that have assessed the effect of DCR on PCI outcomes.

View Article and Find Full Text PDF
Article Synopsis
  • The study focused on estimating the dose area product (DAP) from pediatric cardiac catheterization procedures at a national center from 1975-2021, emphasizing trends in radiation exposure.
  • A significant reduction of 71% in median DAP was observed from 1975-1989 to 2011-2021, with age and body weight being key factors influencing exposure levels.
  • The findings highlight advancements in technology and clinical practices, while the initial high DAP in earlier years was largely due to cine acquisition methods, which are essential for understanding radiation risks in pediatric patients.
View Article and Find Full Text PDF

Development and international multicentre pilot testing of a postal dosimetry audit methodology for high dose rate brachytherapy.

Phys Imaging Radiat Oncol

October 2024

International Atomic Energy Agency, Department of Nuclear Sciences and Applications, Division of Human Health, Vienna, Austria.

Background And Purpose: Dosimetry audits are essential for reducing errors in brachytherapy. A postal dosimetry audit methodology was developed and tested in an international multicentre pilot, to assess the accuracy of the Reference Air Kerma Rate of Ir and Co brachytherapy sources.

Materials And Methods: A compact phantom made of polymethyl methacrylate was developed to accommodate two catheters, a radiophotoluminescence dosimeter (RPLD) for dose measurements and a Gafchromic (RTQA2) film strip for source position verification.

View Article and Find Full Text PDF

Purpose: Before this study, no institution in China had undertaken the calculation and official establishment of reference values for the reference air kerma rate associated with high-dose rate Ir sources used in brachytherapy. This research, carried out at the National Institute of Metrology (NIM) in China, has successfully established an Ir reference radiation facility. Consequently, it has achieved the absolute measurement of the reference air kerma rate for high-dose rate brachytherapy using Ir sources.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!