This study was conducted on the Fukushima Medical University (FMU) premises (in Fukushima City, Fukushima Prefecture) about four years after the Fukushima Daiichi Nuclear Power Plant accident. Its objectives were (1) to create a map of the ambient gamma dose rate (air-kerma rate) distribution, (2) to evaluate the air-kerma rate originating from natural radionuclides, and (3) to investigate the effects of snow cover on changes in the air-kerma rate. This man-borne survey revealed that the air-kerma rate varies widely, ranging from 0.038 μGy h(-1) to 0.520 μGy h(-1), and is higher on grass than on the other investigated surface types, such as soil, asphalt, and bricks. In this area, the mean air-kerma rate from natural radiation was evaluated to be 0.03 ± 0.01 μGy h(-1), which is close to 0.04 μGy h(-1), which was measured in central Fukushima City by a local authority.Furthermore, snowfall was found to reduce the air-kerma rate by 5%-30%. This reduction was attributed to attenuation of the primary radiation while passing through the snow cover, and the measured contribution of scattered radiation to the air-kerma rate reduction was small. The reduction rate was found to depend on the initial snow depth but to maintain a similar value for a couple of days, after the snow had partially melted and its depth had decreased. Finally, analysis of the daily dose due to external exposure received on the FMU premises revealed that no further health effects due to chronic radiation exposure at this site are to be expected.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5131576 | PMC |
http://dx.doi.org/10.5387/fms.2015-16 | DOI Listing |
J Cardiothorac Surg
December 2024
Department of Surgery, Teikyo University School of Medicine, 2-11-1 Kaga, Itabashi-ku, Tokyo, 173-8605, Japan.
Background: Several methods can be used to intraoperatively identify pulmonary lesion using radiation technology. However, little is known about patient radiation exposure during chest surgery. We aimed to measure patients' radiation exposure from cone-beam computed tomography (CBCT) used in a hybrid operating room.
View Article and Find Full Text PDFBMC Cardiovasc Disord
November 2024
Yale University School of Medicine, New Haven, CT, USA.
Background: Contrast-induced acute kidney injury (CI-AKI) is one of the complications of percutaneous coronary intervention (PCI) with high financial burden and poor outcomes. Dynamic coronary roadmap (DCR) is one of the augmentation tools that can provide a dynamic clear coronary mapping with the potential to reduce contrast use and CI-AKI incidence. Herein, we aim to systematically investigate the studies that have assessed the effect of DCR on PCI outcomes.
View Article and Find Full Text PDFJ Radiol Prot
December 2024
Department of Optometry, Radiography and Lighting Design, University of South-Eastern Norway (USN), Drammen, Norway.
Phys Imaging Radiat Oncol
October 2024
International Atomic Energy Agency, Department of Nuclear Sciences and Applications, Division of Human Health, Vienna, Austria.
Background And Purpose: Dosimetry audits are essential for reducing errors in brachytherapy. A postal dosimetry audit methodology was developed and tested in an international multicentre pilot, to assess the accuracy of the Reference Air Kerma Rate of Ir and Co brachytherapy sources.
Materials And Methods: A compact phantom made of polymethyl methacrylate was developed to accommodate two catheters, a radiophotoluminescence dosimeter (RPLD) for dose measurements and a Gafchromic (RTQA2) film strip for source position verification.
Brachytherapy
January 2025
School of Science, Hebei University of Science and Technology, Shijiazhuang, China.
Purpose: Before this study, no institution in China had undertaken the calculation and official establishment of reference values for the reference air kerma rate associated with high-dose rate Ir sources used in brachytherapy. This research, carried out at the National Institute of Metrology (NIM) in China, has successfully established an Ir reference radiation facility. Consequently, it has achieved the absolute measurement of the reference air kerma rate for high-dose rate brachytherapy using Ir sources.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!