Emesis as a Screening Diagnostic for Low Dose Rate (LDR) Total Body Radiation Exposure.

Health Phys

*Department of Radiation Oncology, Emory University, 1365 Clifton Rd NE, Atlanta, GA 30322; †Winship Cancer Institute, Emory University,1365 Clifton Rd NE, Atlanta, GA 30322; ‡Biostatistics and Bioinformatics, Emory University, 1534 Clifton Rd NE, Atlanta, GA 30322; §EPR Center at Dartmouth, One Medical Center Dr, Lebanon, NH 03766.

Published: April 2016

AI Article Synopsis

Article Abstract

Current radiation disaster manuals list the time-to-emesis (TE) as the key triage indicator of radiation dose. The data used to support TE recommendations were derived primarily from nearly instantaneous, high dose-rate exposures as part of variable condition accident databases. To date, there has not been a systematic differentiation between triage dose estimates associated with high and low dose rate (LDR) exposures, even though it is likely that after a nuclear detonation or radiologic disaster, many surviving casualties would have received a significant portion of their total exposure from fallout (LDR exposure) rather than from the initial nuclear detonation or criticality event (high dose rate exposure). This commentary discusses the issues surrounding the use of emesis as a screening diagnostic for radiation dose after LDR exposure. As part of this discussion, previously published clinical data on emesis after LDR total body irradiation (TBI) is statistically re-analyzed as an illustration of the complexity of the issue and confounding factors. This previously published data includes 107 patients who underwent TBI up to 10.5 Gy in a single fraction delivered over several hours at 0.02 to 0.04 Gy min. Estimates based on these data for the sensitivity of emesis as a screening diagnostic for the low dose rate radiation exposure range from 57.1% to 76.6%, and the estimates for specificity range from 87.5% to 99.4%. Though the original data contain multiple confounding factors, the evidence regarding sensitivity suggests that emesis appears to be quite poor as a medical screening diagnostic for LDR exposures.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4770573PMC
http://dx.doi.org/10.1097/HP.0000000000000476DOI Listing

Publication Analysis

Top Keywords

screening diagnostic
16
dose rate
16
emesis screening
12
low dose
12
diagnostic low
8
rate ldr
8
ldr total
8
total body
8
radiation exposure
8
radiation dose
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!