A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Respiratory System Function in Patients after Aortic Valve Replacement through Right Anterior Minithoracotomy. | LitMetric

 The aim of the study was to analyze respiratory system function after minimally invasive aortic valve replacement through right anterior minithoracotomy (RAT-AVR).  An observational study of 187 patients electively scheduled for RAT-AVR between January 2010 and December 2013. Pulmonary complications were analyzed and spirometry examinations were performed preoperatively, 1 week, 1 month, and 3 months after surgery.  Hospital mortality was 1.1%. A double-lumen intratracheal tube was used in 88.2% and single-lumen intratracheal tube was used in 11.8% of patients. Pulmonary complications occurred in 10.8% of the patients. Prolonged (>24 hours) mechanical ventilation time was present in five patients (2.7%). The reasons were stroke ( = 1), perioperative myocardial infarction ( = 2), and pneumothorax ( = 2). Right pleural effusion, which occurred in 7.7% ( = 14) of patients, was the most frequent respiratory system complication. One week after surgery, the spirometry parameters decreased in comparison to the preoperative period, then after 3 months statistically significant improvement occurred; however, the spirometry parameters still had not returned to preoperative values. Multivariable median regression analysis shows that the presence of chronic obstructive pulmonary disease and pulmonary complications were associated with lower values of forced expiratory volume in 1 second after surgery. There was no statistically significant difference regarding spirometry values or incidence of pulmonary complications after surgery between patients in whom single-lung or double-lung ventilation was applied.  Pulmonary functional status measured with spirometry parameters was diminished after RAT-AVR surgery. Single-lung ventilation did not result in a higher rate of respiratory complications after RAT-AVR surgery.

Download full-text PDF

Source
http://dx.doi.org/10.1055/s-0036-1571827DOI Listing

Publication Analysis

Top Keywords

pulmonary complications
16
respiratory system
12
spirometry parameters
12
system function
8
aortic valve
8
valve replacement
8
replacement anterior
8
anterior minithoracotomy
8
intratracheal tube
8
rat-avr surgery
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!