A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Spot event detection along a large-scale sensor based on ultra-weak fiber Bragg gratings using time-frequency analysis. | LitMetric

A simple scheme for interrogating a 5 m long photonics device and its potential applications to quasi-distributed fiber sensing is proposed. The sensor consists of an array of 500 identical, very weak fiber Bragg gratings (FBGs). The gratings are 9 mm long and have been serially written in cascade along a single optical fiber. The measurement system is based on a combination of optical time domain reflectometry and frequency scanning of the interrogating pulse. The time-frequency analysis is performed by launching an optical pulse into the sensor and retrieving and analyzing the back-reflected signal. The measurement of the temperature, length, and position of spot events along the sensors is demonstrated with good accuracy. As both spatial and temperature resolution of the method depend on the input pulse duration, the system performance can be controlled and optimized by properly choosing the temporal duration of the interrogating pulse. A spatial resolution of 9 mm (ultimately dictated by one grating length) has been obtained with an 80 ps optical pulse, while a temperature resolution of less than 0.42 K has been demonstrated using a 500 ps incident pulse. The sensor proposed proves to be simple, robust, and polarization insensitive and alleviates the instrumentation complexity for distributed sensing applications.

Download full-text PDF

Source
http://dx.doi.org/10.1364/AO.55.001054DOI Listing

Publication Analysis

Top Keywords

fiber bragg
8
bragg gratings
8
time-frequency analysis
8
interrogating pulse
8
optical pulse
8
pulse sensor
8
temperature resolution
8
pulse
6
spot event
4
event detection
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!