Objective: Off-pump coronary artery bypass grafting in patients with left ventricular dysfunction has proven to be advantageous. However, it carries risk of emergency conversion to cardiopulmonary bypass. We have successfully used an intra-aortic balloon pump to prevent such conversion. The objective of the present study was to evaluate if intravenous nicorandil infusion reduces the incidence of intraoperative intra-aortic balloon pump insertion.
Methods: Consecutive cases of isolated off-pump coronary artery bypass surgery performed by a single surgeon were studied. Patients were divided into two groups. The first group did not receive nicorandil, and the second group received intraoperative nicorandil infusion (started in the operating room after central line insertion).
Results: A total of 375 patients were included in the study. Four patients in the non-nicorandil group and the patients in nicorandil group were on preoperative intra-aortic balloon pump and hence excluded from the study. After routine use of nicorandil infusion, incidence of intra-aortic balloon pump insertion during off-pump coronary artery bypass surgery decreased from 12.4% (21/169) to 2.9% (6/206).
Conclusions: Nicorandil infusion significantly (P = 0.007) reduced the incidence of intra-aortic balloon pump insertion in our series. In patients with left ventricular dysfunction (ejection fraction ≤ 30%), this difference (P = 0.008) assumes a special significance as off-pump bypass surgery is considered high risk in this subset. Nicorandil is an inexpensive drug, and the reduction in cost of surgery by avoiding intra-aortic balloon pump insertion is an added advantage. The use of nicorandil infusion during off-pump coronary artery bypass may result in favorable patient outcomes by reducing invasive intra-aortic balloon pump insertion during off-pump coronary artery bypass grafting.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/IMI.0000000000000242 | DOI Listing |
Front Cardiovasc Med
January 2025
Department of Intensive Care Medicine, Taizhou Central Hospital (Taizhou University Hospital), Taizhou, Zhejiang, China.
A young female patient suffered cardiogenic shock after undergoing surgery for an ectopic pregnancy. Coronary artery computed tomography angiography (CTA) revealed a left main artery (LM) originating from the right coronary sinus and traveling between the aorta and pulmonary artery. We successfully resuscitated the patient with mechanical circulatory support using veno-arterial extracorporeal membrane oxygenation (VA-ECMO) and an intra-aortic balloon pump (IABP).
View Article and Find Full Text PDFIntroduction: In patients with acute myocardial infarction and cardiogenic shock (AMICS), the intra-aortic balloon pump (IABP) remains the most commonly used form of mechanical circulatory support (MCS). However, information on the characteristics of non-responders is limited. This study evaluated the risk factors associated with 30-day mortality in a cohort of patients with AMICS, on IABP support.
View Article and Find Full Text PDFInt J Numer Method Biomed Eng
January 2025
Department of Cardiology, First Medical Center, General Hospital of Chinese people's Liberation Army, Beijing, China.
The intra-aortic balloon pump (IABP) is a widely-used mechanical circulatory support device that enhances hemodynamics in patients with heart conditions. Although the IABP is a common clinical tool, its effectiveness in enhancing outcomes for patients with acute myocardial infarction and cardiogenic shock remains disputed. This study aimed to assess the effectiveness of intra-aortic dual-balloon pump (IADBP) and its impact on aortic hemodynamics compared with an IABP.
View Article and Find Full Text PDFJ Cardiothorac Vasc Anesth
December 2024
Kore University, Enna, Italy and Centro Cuore GB Morgagni, Catania, Italy.
Objectives: The benefit of combining multiple mechanical circulatory support (MCS) systems in patients with cardiogenic shock (CS) is debated. This review examines patient characteristics across studies to identify differences and assesses if patients with a higher-risk clinical profile receive Impella unloading.
Design: A systematic review and meta-analysis was conducted to examine if there were significant differences in baseline clinical parameters among patients receiving MCS in addition to venoarterial extracorporeal membrane oxygenation (VA ECMO).
Catheter Cardiovasc Interv
January 2025
Carl and Edyth Lindner Research Center, Christ Hospital, Cincinnati, Ohio, USA.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!