AI Article Synopsis

Article Abstract

Peripheral catheter embolization to the heart is common but infrequently reported. In view of the hazardous complications of thrombosis, embolism, infection, arrhythmia and even death, percutaneous retrieval of such foreign bodies is usually attempted. Previously reported percutaneous technique of retrieval mainly involved the snaring technique. Herein, we report a novel nonsurgical retrieval technique for successful removal of a 46 cm long embolized intracardiac peripherally inserted central catheter by utilizing a flexible biopsy forceps. To the best of our knowledge, the use of flexible biopsy forceps for retrieval has hitherto been unreported and this case report therefore adds to the repertoire of percutaneous retrieval techniques for safe and easy removal of embolized catheters to the heart.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4738497PMC
http://dx.doi.org/10.4103/1995-705X.172204DOI Listing

Publication Analysis

Top Keywords

flexible biopsy
12
biopsy forceps
12
embolized intracardiac
8
intracardiac peripherally
8
peripherally inserted
8
inserted central
8
central catheter
8
percutaneous technique
8
utilizing flexible
8
percutaneous retrieval
8

Similar Publications

The prevalent tumor-supporting glioblastoma-associated macrophages (GAMs) promote glioblastoma multiforme (GBM) progression and resistance to multiple therapies. Repolarizing GAMs from tumor-supporting to tumor-inhibiting phenotype may troubleshoot. However, sufficient accumulation of drugs at the GBM site is restricted by blood-brain barrier (BBB).

View Article and Find Full Text PDF

Purpose: Research has shown that prolonged endotracheal intubation can increase risk of aspiration following extubation. This study examined the relationship between swallowing and intubation among patients with COVID-19. We investigated the association between the duration of intubation and time until an oral diet was safely initiated and the correlation between the length of intubation and reduced sensation with aspiration as seen on flexible endoscopic evaluation of swallowing (FEES)/videofluoroscopic swallowing study (VFSS).

View Article and Find Full Text PDF

Engineering Peptide-Based Molecular Baits for Targeted Fishing and Protein Profiling of Exosomes as a Liquid Biopsy for Gastrointestinal Adenocarcinoma.

Anal Chem

January 2025

Beijing National Laboratory for Molecular Sciences, CAS Key Laboratory of Analytical Chemistry for Living Biosystems, CAS Research/Education Center for Excellence in Molecular Sciences, Institute of Chemistry, Chinese Academy of Sciences, Beijing 100190, China.

High-performance isolation of exosomes as a promising liquid biopsy target is of great importance for both fundamental research and clinical applications. This is, however, challenged by the prevalent heterogeneity of exosomes and the highly complex nature of biosamples. Here, we introduce the use of a CD81-targeting peptide as a building block for tailoring molecular baits for exosome isolation and payload analysis in clinical biofluids.

View Article and Find Full Text PDF

Purpose: Transurethral resection of bladder tumor (TURBT) is the initial staging procedure for new bladder cancers (BCs). For muscle-invasive bladder cancers (MIBCs), TURBT may delay definitive treatment. We investigated whether definitive treatment can be expedited for MIBC using flexible cystoscopic biopsy and multiparametric magnetic resonance imaging (mpMRI) for initial staging.

View Article and Find Full Text PDF

Tracheal adenoid cystic carcinoma is a rare malignancy. We report the case of a 65-year-old male who presented to our department due to a 3-month history of mild dysphagia without other associated symptoms. The neck, laryngeal, and hypopharyngeal examinations were normal.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!