A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Autotransplantation of Premolars With a 3-Dimensional Printed Titanium Replica of the Donor Tooth Functioning as a Surgical Guide: Proof of Concept. | LitMetric

Autotransplantation of Premolars With a 3-Dimensional Printed Titanium Replica of the Donor Tooth Functioning as a Surgical Guide: Proof of Concept.

J Oral Maxillofac Surg

Maxillofacial Surgeon, Professor, and Department Head, Department of Oral and Maxillofacial Surgery, Leiden University Medical Center, Leiden, The Netherlands. Electronic address:

Published: June 2016

Purpose: Autotransplantation of premolars is a good treatment option for young patients who have missing teeth. This study evaluated the use of a preoperatively 3-dimensional (3D)-printed replica of the donor tooth that functions as a surgical guide during autotransplantation.

Materials And Methods: Five consecutive procedures were prospectively observed. Transplantations of maxillary premolars with optimal root development were included in this study. A 3D-printed replica of the donor tooth was used to prepare a precisely fitting new alveolus at the recipient site before extracting the donor tooth. Procedure time, extra-alveolar time, and number of attempts needed to achieve a good fit of the donor tooth in the new alveolus were recorded.

Results: For each transplantation procedure, the surgical time was shorter than 30 minutes. An immediate good fit of the donor tooth in the new alveolus was achieved with an extra-alveolar time shorter than 1 minute for all transplantations.

Conclusion: These results show that the extra-alveolar time is very short when the surgical guide is used; therefore, the chance of iatrogenic damage to the donor tooth is minimized. The use of a replica of the donor tooth makes the autotransplantation procedure easier for the surgeon and facilitates optimal placement of the transplant.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.joms.2016.01.030DOI Listing

Publication Analysis

Top Keywords

donor tooth
32
replica donor
16
surgical guide
12
extra-alveolar time
12
autotransplantation premolars
8
donor
8
tooth
8
3d-printed replica
8
good fit
8
fit donor
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!