A case is described of aortic stenosis that was initially treated with transcatheter aortic valve implantation (TAVI) due to a high-risk profile. Following dysfunction of the TAVI prosthesis, conventional aortic valve replacement (AVR) was successfully performed; the subsequent postoperative course was uneventful. In conclusion, the target population for TAVI must be more accurately specified, with further research helping to define whether AVR or TAVI is the best treatment option for 'intermediate-risk' patients.

Download full-text PDF

Source

Publication Analysis

Top Keywords

aortic valve
12
conventional aortic
8
valve replacement
8
replacement displacement
4
displacement percutaneously
4
percutaneously implanted
4
aortic
4
implanted aortic
4
aortic prosthesis
4
prosthesis case
4

Similar Publications

Objective: To compare outcomes of aortic valve replacement (AVR) in patients with pure aortic stenosis (Pure AS) and those with pure aortic regurgitation (Pure AR) or mixed AS and AR (MAVD) in the COMMENCE trial.

Methods: Of 689 patients who underwent AVR in the COMMENCE trial, patients with moderate or severe AR with or without AS (Pure AR + MAVD; n = 135) or Pure AS (n = 323) were included. Inverse probability of treatment weighting Kaplan-Meier survival curves were used for time-to-event endpoints, and longitudinal changes in hemodynamics were evaluated using mixed-effects models.

View Article and Find Full Text PDF

Objective: The superior transseptal approach to mitral valve surgery offers improved exposure compared with left atriotomy; however, concerns remain regarding postoperative arrhythmias and pacemaker placement. This study investigates intraoperative parameters and postoperative outcomes in these approaches.

Methods: Retrospective review of 259 adults undergoing isolated mitral valve repair or replacement over a 10-year period was performed.

View Article and Find Full Text PDF

Objective: Postoperative atrial fibrillation (POAF) is a common complication after cardiac surgery that is associated with other adverse outcomes. Recent studies have shown that drainage of pericardial effusion by a posterior pericardial incision reduces the incidence of POAF. An alternative approach is a chest tube placed posteriorly in the pericardium.

View Article and Find Full Text PDF

Objective: The study objective was to investigate the effect of free-edge length on valve performance in bicuspidization repair of congenitally diseased aortic valves.

Methods: In addition to a constructed unicuspid aortic valve disease model, 3 representative groups-free-edge length to aortic diameter ratio 1.2, 1.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!