Background: Inferior angle of scapula (IAS) fractures are rare, with very few cases reported. They typically present with pain, loss of shoulder motion, and scapula winging. Operative and nonoperative treatments have been trialed with varying success. The aim of this study was to gather data relating to IAS fractures to develop evidence-based treatment guidelines as none are currently available.
Methods: A search was conducted of the PubMed and Google Scholar databases to identify cases of IAS fractures. Data collected about each case included age and gender of the patient, mechanism of injury, fracture displacement, treatment, and outcome. The authors report 2 additional IAS fracture cases.
Results: Ten cases were identified for inclusion in this study, 8 from the literature and 2 described by the authors. Of the 10 cases, 7 described displaced IAS fractures and 3 described undisplaced fractures. All displaced fractures treated nonoperatively resulted in a painful nonunion. All that underwent operative fixation, whether acutely or after failed nonoperative treatment, had resolution of pain and a good functional outcome. All undisplaced fractures were treated nonoperatively; 1 had persisting pain. Surgical exploration identified the fracture fragment attached to serratus anterior in 2 cases and attached to both serratus anterior and latissimus dorsi in 2 cases.
Discussion And Conclusions: There are limited data available about IAS factures. From the cases reviewed, treatment recommendations include the following: (1) displaced IAS fractures should undergo operative fixation to prevent the development of a painful nonunion; (2) suture repair provides adequate fixation; and (3) undisplaced fractures have a variable outcome when treated nonoperatively.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jse.2015.11.007 | DOI Listing |
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi
September 2024
Department of Orthopaedics, the First Affiliated Hospital of Bengbu Medical University, Anhui Key Laboratory of Tissue Transplantation, Bengbu Anhui, 233004, P. R. China.
Objective: To investigate the application experiences and effectiveness of the infra-acetabular screw (IAS) placement technique in acetabular fracture surgery.
Methods: A clinical data of 34 patients with complex acetabular fractures with anterior and posterior columns separation, who were admitted between January 2019 and October 2023 and treated with IAS fixation, was retrospectively analyzed. There were 23 males and 11 females with an average age of 55.
Arch Orthop Trauma Surg
October 2024
Department of Orthopaedic and Trauma Surgery, Medical University Innsbruck, Anichstraße 35, Innsbruck, 6020, Austria.
Acetabular fracture surgery follows the primary aim of anatomic reduction and rigid stable fixation of the fracture. Infraacetabular screws (IAS) allow for an increased stability of the acetabular fixation by closing the periacetabular fixation frame without requiring an additional posterior approach. The osseous screw corridor for infraacetabular screws use the transition zone between the acetabular ring and the obturator ring.
View Article and Find Full Text PDFArch Orthop Trauma Surg
June 2024
Department of Trauma and Orthopaedic Surgery, University Medical Center Hamburg-Eppendorf, Martinistrasse 52, 20246, Hamburg, Germany.
Introduction: Traditionally, plate osteosynthesis of the anterior column combined with an antegrade posterior column screw is used for fixation of anterior column plus posterior hemitransverse (ACPHT) acetabulum fractures. Replacing the posterior column screw with an infraacetabular screw could improve the straightforwardness of acetabulum surgery, as it can be inserted using less invasive approaches, such as the AIP/Stoppa approach, which is a well-established standard approach. However, the biomechanical stability of a plate osteosynthesis combined with an infraacetabular screw instead of an antegrade posterior column screw is unknown.
View Article and Find Full Text PDFJ Orthop Surg Res
February 2024
Department of Anatomy, Guangdong Provincial Key Laboratory of Digital Medicine and Biomechanics, Guangdong Engineering Research Center for Translation of Medical 3D Printing Application, National Virtual and Reality Experimental Education Center for Medical Morphology, School of Basic Medical Sciences, Southern Medical University, No. 1023, South Shatai Road, Baiyun District, Guangzhou, 510515, Guangdong, China.
Background: Insufficient interfragmentary compression force (IFCF) frequently leads to unstable fixation of osteoporotic lateral tibial plateau fractures (OLTPFs). A combined cancellous lag screw (CCLS) enhances IFCF; however, its effect on OLTPF fixation stability remains unclear. Therefore, we investigated the effect of CCLS on OLTPF stability using locking plate fixation (LPF).
View Article and Find Full Text PDFInjury
June 2024
Department of Orthopedic Surgery, Science of Functional Recovery and Reconstruction, Faculty of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University, 2-5-1 Shikata, Kitaku, Okayama City, Okayama, 700-8558 Japan.
Background: In acetabular fracture surgery, an infra-acetabular screw (IAS) is inserted from the anterior to the posterior column through the infra-acetabular corridor to stabilize both columns. Although the IAS is useful for increasing fixation strength, proper placement requires proficiency and often results in extraosseous screw penetration. The complex anatomy of the infra-acetabular corridor and difficult intraoperative detection of the ideal insertion point and angle make proper placement of the IAS challenging.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!