Background: Prior studies have demonstrated conflicting results regarding the relationship between corneal biomechanical properties and refractive error. Thus, the purpose of this study was to compare the corneal biomechanical parameters of myopes and emmetropes.
Methods: Ninety-four subjects with varying degrees of myopia (aged 29 to 74 years, spherical equivalent [SE] -0.5 to -17.5 D) and 25 emmetropes (aged 19 to 75 years, SE: -0.5 to +0.5 D) presenting at the Queen Mary Hospital, Hong Kong were recruited sequentially for this prospective study. All patients were phakic with no history of coexisting ocular disease. The corneal biomechanical parameters of the right eye of each subject were analysed using the Corvis ST non-contact tonometer. Intraocular pressure (IOP) was measured using both the Corvis ST and the Topcon Non-Contact Tonometer CT-80. Refractive error was measured by non-cycloplegic subjective and objective refractometry.
Results: High myopes (SE greater than -6.00 D) demonstrated greater mean outward applanation velocities (p < 0.001) and peak distance measurements (p = 0.009) compared to both low to moderate myopes (SE -0.50 to -6.00 D) and emmetropes. Both outward applanation velocity and peak distance were moderately correlated with refractive error (p ≤ 0.001), strongly correlated with IOP and weakly correlated with central corneal thickness. There were no statistically significant differences in age, IOP or central corneal thickness among emmetropes, low to moderate myopes or high myopes.
Conclusion: Within this study of Chinese subjects, high myopes demonstrate greater corneal mean outward applanation velocity on Corvis ST testing, than emmetropes. In particular, those with high myopia (SE greater than -6.00 D) show a distinct corneal biomechanical profile relative to those with either emmetropia or low to moderate myopia using the Corvis ST.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/cxo.12341 | DOI Listing |
Sci Rep
December 2024
Imaging, Biomechanics and Mathematical Modelling Solutions Lab, Narayana Nethralaya Foundation, Bangalore, India.
An induced cylinder and spherical power after implantation with an extended depth of focus (EDOF) and enhanced monofocal intraocular lens (IOL) could improve distance, intermediate (60 cm) and near (40 cm) visual acuity (VA). In this prospective study, forty eyes with Eyhance EDOF IOL (Johnson and Johnson, USA) and 40 eyes with Vivity EDOF IOL (Alcon Laboratories Inc. USA) were included.
View Article and Find Full Text PDFPain Rep
February 2025
Pain Research Institute, Institute of Life Course and Medical Sciences, University of Liverpool, Liverpool, United Kingdom.
Introduction: Pain phenomenology in patients with fibromyalgia syndrome (FMS) shows considerable overlap with neuropathic pain. Altered neural processing leading to symptoms of neuropathic pain can occur at the level of the spinal cord, and 1 potential mechanism is spinal disinhibition. A biomarker of spinal disinhibition is impaired H-reflex rate-dependent depression (HRDD).
View Article and Find Full Text PDFAm J Ophthalmol
December 2024
Clinical College of Ophthalmology, Tianjin Medical University, Tianjin, China; School of Medicine, Nankai University, Tianjin, China; Tianjin Eye Hospital, Tianjin Key Laboratory of Ophthalmology and Visual Science, Tianjin Eye Institute, Nankai University Affiliated Ophthalmology Hospital, Tianjin, China; Nankai Eye Institute, Nankai University, Tianjin, China. Electronic address:
Purpose: To analyze the effect of individual parameters on the postoperative refractive outcomes of small incision lenticule extraction in myopic eyes using machine learning methods.
Design: Retrospective Clinical Cohort Study METHODS: We included 477 patients (922 eyes) of small incision lenticule extraction at Tianjin Ophthalmology Hospital and divided the patients into two groups to analyzed the factors affecting postoperative refractive outcomes based on the label of postoperative spherical equivalent (SE) ≤ -0.50D.
Sci Rep
December 2024
Laboratory of Biology, Engineering, and Imaging for Ophthalmology, BiiO, Faculty of Medicine, University of Jean Monnet, 10 rue de la Marandière, 42270, Saint-Priest en Jarez, France.
The cornea, the anterior meniscus-shaped transparent and refractive structure of the eyeball, is the first mechanical barrier of the eye. Its functionality heavily relies on the health of its endothelium, its most posterior layer. The treatment of corneal endothelial cells (CECs) deficiency is allogeneic corneal graft using stored donor corneas.
View Article and Find Full Text PDFMar Drugs
November 2024
Tissue Engineering Group, Department of Histology, Faculty of Medicine, University of Granada, E18016 Granada, Spain.
Cornea tissue engineering is strictly dependent on the development of biomaterials that fulfill the strict biocompatibility, biomechanical, and optical requirements of this organ. In this work, we generated novel biomaterials from the squid gladius (SG), and their application in cornea tissue engineering was evaluated. Results revealed that the native SG (N-SG) was biocompatible in laboratory animals, although a local inflammatory reaction was driven by the material.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!