Intraoral versus extraoral bitewing radiography in detection of enamel proximal caries: an ex vivo study.

Dentomaxillofac Radiol

Department of Oral and Maxillofacial Radiology, Faculty of Dentistry, Ain Shams University, Cairo, Egypt.

Published: June 2016

Objective: To compare the diagnostic accuracy of digital intraoral and extraoral bitewing (EO BW) radiography in the detection of enamel proximal caries regardless of their ability to separate contacts.

Methods: Artificial caries with different degrees of decalcification was induced in 80 human sound premolars and molars using formic acid. Intraoral radiographs were taken with photostimulable phosphor plate (PSP) and complementary metal oxide semiconductor (CMOS), using the paralleling bitewing technique. Extraoral bitewing radiographs were obtained using Sirona digital panoramic X-ray unit (Sirona Siemens, Bensheim, Germany). In total, 160 proximal surfaces were assessed by 2 observers twice. Area under the receiver operating characteristic curve (Az) values for each image type, observer and reading were compared using z-tests, with a significance level of p ≤ 0.05. Sensitivity, specificity, positive-predictive value and negative-predictive value for each observer and reading were calculated.

Results: Spearman's test showed a strong positive correlation between the duration of demineralization and histological grading of carious teeth surfaces. For the three radiographic techniques, intraobserver reliability was strong to excellent. Moreover, interobserver agreement was strong. The differences between all detection methods were not statistically significant (p > 0.05). Intraoral bitewing using CMOS sensor had the highest sensitivity while EO BW had the highest specificity in the detection of incipient proximal caries.

Conclusions: Within the limits of the ex vivo design, the difference in diagnostic accuracy between the three radiographic techniques was not significant. EO BW could be used in the detection of enamel proximal caries with results comparable with intraoral bitewing with PSP plate and CMOS sensor.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4846173PMC
http://dx.doi.org/10.1259/dmfr.20150326DOI Listing

Publication Analysis

Top Keywords

extraoral bitewing
12
detection enamel
12
enamel proximal
12
proximal caries
12
bitewing radiography
8
radiography detection
8
diagnostic accuracy
8
observer reading
8
three radiographic
8
radiographic techniques
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!