AI Article Synopsis

  • The study aimed to evaluate the frequency and risk factors of complications from fine-needle aspiration biopsy (FNAB) in Japanese patients with thyroid nodules.
  • A total of 653 patients and 742 nodules were analyzed, finding low prevalence rates of complications at 0.13% and 0.94%, with no identified risk factors.
  • The study concludes that FNAB complications are rare when preventive measures are taken and that sudden bright spots seen on ultrasound may be due to air or fluid contamination.

Article Abstract

Objectives: The purpose of this study was to assess the frequency of and risk factors for fine-needle aspiration biopsy (FNAB)-related complications in Japanese patients with thyroid nodules evaluated by standard FNAB techniques.

Methods: Six hundred fifty-three consecutive Japanese patients with 742 nodules who had undergone FNAB were enrolled. Nodule characteristics were evaluated, and thyroid volumes were measured. Fine-needle aspiration biopsy-related complications were identified on the basis of sonographic findings and patients' conditions after undergoing FNAB. Comparisons of patients' backgrounds and nodule characteristics were made between those with and without complications.

Results: The prevalence rates for FNAB-related complications, including acute transient thyroid swelling after FNAB and appearance of anechoic lesions, were 0.13% and 0.94%. In this study, we could not identify risk factors for FNAB-related complications. The sudden appearance of bright hyperechoic foci within the thyroid immediately after biopsy was reported as an FNAB-related unfamiliar appearance in 5 cases. Experimental FNA using resected porcine thyroid tissue suggested that the etiology of the hyperechoic appearance may be artificial air bubbles or reversed flow of aspirated fluid.

Conclusions: Fine-needle aspiration biopsy-related complications are rare if preventive measures are performed and are not specific to Japanese patients with thyroid nodules. The sudden appearance of bright hyperechoic foci may be cause by contamination from air or fluid.

Download full-text PDF

Source
http://dx.doi.org/10.7863/ultra.15.06017DOI Listing

Publication Analysis

Top Keywords

fine-needle aspiration
16
fnab-related complications
12
japanese patients
12
aspiration biopsy
8
risk factors
8
patients thyroid
8
thyroid nodules
8
nodule characteristics
8
aspiration biopsy-related
8
biopsy-related complications
8

Similar Publications

Unlabelled: SARS-CoV-2 mRNA vaccines induce robust and persistent germinal centre (GC) B cell responses in humans. It remains unclear how the continuous evolution of the virus impacts the breadth of the induced GC B cell response. Using ultrasound-guided fine needle aspiration, we examined draining lymph nodes of nine healthy adults following bivalent booster immunization.

View Article and Find Full Text PDF

Parathyroid adenoma is a common endocrine disorder, but its intrathyroid presentation is relatively rare. The traditional approach, such as thyroid blind lobectomy, is the most frequent modality of treatment due to the possible unclear localization of the adenoma in the preoperative workup. This increases the risk of unnecessary probability of hypothyroidism.

View Article and Find Full Text PDF

Purpose: In solid pancreatic lesions (SPLs), we compared the diagnostic efficacy of a 19G fine-needle aspiration (FNA) needle and a 22G ProCore fine-needle biopsy (FNB) needle, We also compared the specimen quality between the standard suction (SS) technique and heparinized wet-suction (HWS) technique.

Methods: All cases of endoscopic ultrasound-guided tissue acquisition (EUS-TA) by 19G FNA or 22G FNB for SPLs in a single-centre hospital were retrospectively reviewed. The diagnostic yield was compared between the 19G and 22G groups.

View Article and Find Full Text PDF

Renal cell carcinoma metastasis to the thyroid gland: a case report.

J Med Case Rep

December 2024

Laboratory of Pathology Pathology, "CSD Health Care", Kiev, Ukraine.

Background: In this article, we report a case of renal cell carcinoma metastasis to the thyroid gland. Occult lesions of the thyroid were treated with a thyroidectomy. The case history presented below describes the patient's pathway and subsequent results.

View Article and Find Full Text PDF

Flow cytometry immunophenotypic analysis is an important and indispensable tool in the diagnosis of mature B-cell lymphomas/leukemias, particularly for small fine needle aspiration and needle core biopsy specimens which are becoming increasingly popular for diagnostic purposes. Flow cytometry immunophenotyping (FCI) has several advantages. Given its multiparametric nature, FCI can analyze the expression of multiple antigens simultaneously on the same cell of interest, qualitatively and quantitively.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!

A PHP Error was encountered

Severity: Notice

Message: fwrite(): Write of 34 bytes failed with errno=28 No space left on device

Filename: drivers/Session_files_driver.php

Line Number: 272

Backtrace:

A PHP Error was encountered

Severity: Warning

Message: session_write_close(): Failed to write session data using user defined save handler. (session.save_path: /var/lib/php/sessions)

Filename: Unknown

Line Number: 0

Backtrace: