Three-dimensional imaging modalities have been reported to be more accurate than panoramic radiographs (PR) for the assessment of bone components of the temporomandibular joint (TMJ). No exact prior information is available that demonstrates which specific limitations occur in terms of TMJ diagnosis when using PR for this purpose. This study aimed to assess the clinical validity of digital panoramic radiography (DPR) when diagnosing morphological disorders of the TMJ using cone-beam computed tomography (CBCT) images as the gold standard. A sample composed of TMJ images (N = 848), including 212 DPR and 212 CBCT images obtained from the same patient, was used to assess any morphological changes in the TMJ. Four appraisers diagnosed all of the DPR images, whereas the CBCT images were used to establish the gold standard. The reliability of each appraiser's response pattern was analyzed using the Kappa test (κ), and diagnostic tests were performed to assess each appraiser's performance using a significance level setting of 5% (α = 0.05). Reliability of each appraiser's response pattern compared to the gold standard ranged from a slight-to-moderate agreement (0.18 ≤ κ ≤ 0.45); and among the different appraisers, the response pattern showed a fair agreement (0.22 ≤ κ ≤ 0.39). Diagnostic tests showed a wide range among the different possible morphological changes diagnosed. DPR does not have validity when diagnosing morphological changes in the TMJ; it underestimates the radiological findings with higher prevalence, and thus, it cannot be used effectively as a diagnostic tool for bone components within this region.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1590/1807-3107BOR-2015.vol29.0120 | DOI Listing |
Ann Neurol
January 2025
Research Unit of Neurology, Neurophysiology and Neurobiology, Department of Medicine and Surgery, Università Campus Bio-Medico di Roma, Rome, Italy.
Objective: Despite diagnostic criteria refinements, Parkinson's disease (PD) clinical diagnosis still suffers from a not satisfying accuracy, with the post-mortem examination as the gold standard for diagnosis. Seminal clinicopathological series highlighted that a relevant number of patients alive-diagnosed with idiopathic PD have an alternative post-mortem diagnosis. We evaluated the diagnostic accuracy of PD comparing the in-vivo clinical diagnosis with the post-mortem diagnosis performed through the pathological examination in 2 groups.
View Article and Find Full Text PDFChempluschem
January 2025
Jiangsu Agri-animal Husbandry Vocational College, Department of Pharmacy, CHINA.
With enrichment of tetracycline (TC) in ecosystems, its accurate detection has become a major concern. Noble-metal nano-particles have attracted great interest as potential materials for sensing applications because of their remarkable electrical properties and adaptability. Herein, a novel electro-chemical detection technique based on carbon nano-tubes (CNTs) as the support material is developed to detect TC with high precision.
View Article and Find Full Text PDFJ Clin Densitom
January 2025
Wayne State University, Detroit, MI, USA.
Body fat percentage (BF%) is routinely measured in athletes to monitor training and dietary interventions. Dual energy x-ray absorptiometry (DXA) is widely considered the gold standard body composition measurement technique, but DXA BF% values measure consistently higher than other techniques. Therefore, the main purpose of this study is to determine the lowest DXA-estimated whole-body fat mass in free-living athletes with unrestricted access to food.
View Article and Find Full Text PDFAnal Chem
January 2025
Beijing National Laboratory for Molecular Sciences, Key Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry, Chinese Academy of Sciences, Beijing 100190, China.
Ligand binding to membrane proteins initiates numerous therapeutic processes. Surface plasmon resonance (SPR), a popular method for analyzing molecular interactions, has emerged as a promising tool for in situ determination of membrane protein binding kinetics owing to its label-free detection, high surface sensitivity, and resistance to intracellular interference. However, the excitation of SPR relies on noble metal films, typically gold, which are biologically incompatible and can cause fluorescence quenching.
View Article and Find Full Text PDFJ Am Podiatr Med Assoc
January 2025
†Jesse Brown VA Medical Center,820 S Damen Ave, Chicago, IL.
Total contact casting is the gold standard for plantar foot ulcers but has been questioned in heel pressure ulcers. Current offloading of heel ulcers is typically removable offloading boots. We describe using a modified posterior splint to offload heel ulcers in nonweightbearing patients.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!